Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: V & L TOOL, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of V & L TOOL, INC. in 2021 MAC ARTHUR ROAD, WAUKESHA, WI 53188 (NAICS 332710). OSHA activity number 331073759.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch V & L Tool, INC. — free Get an email when a new federal OSHA severe-injury report for V & L Tool, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
V & L TOOL, INC.
Site address
2021 MAC ARTHUR ROAD
City
WAUKESHA
State
WI
ZIP
53188
Mailing
2021 MAC ARTHUR ROAD, WAUKESHA, WI 53188
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
85
Ownership type
A

3 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 4 instances 5 exposed
Issued
Jan 27, 2012
Abate by
Apr 30, 2012
Penalty
Initial $2,975 · Current $1,800 Reduced
29 CFR 1910.212(a)(1):     Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by rotating parts:    (a)  In the lathe department, the interlocking mechanism on the Mori Seiki #812 CNC Lathe was removed from the door, allowing the machine to operate with the door open, exposing employees to entanglement hazards.     (b)  In the lathe department, the Okuma LB-8 #806 CNC Lathe was operating with the interlock keyed in the off position, exposing employees to entanglement hazards.     (c)  In the lathe department, the Okuma LB-8 #806 CNC Lathe had an unguarded rotating projection 40 inches off the floor, exposing employees to entanglement hazards.     (d)  In the lathe department, the Okuma LC40 CNC Lathe did not have any interlocking or permanent guards, exposing employees to entanglement hazards.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $2975

1910.303 B01

Other-than-serious 1 instance 1 exposed
Issued
Jan 27, 2012
Abate by
Feb 10, 2012
Penalty
Initial $1,785 · Current $0 Reduced
29 CFR 1910.303(b)(1):     Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:    (a)  In the storage dock area, a RACO metallic utility box had a receptacle with a grounding pin broke off in it and another with a burn mark. The utility box was in service powering a floor fan. Employees were exposed to electrical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (S) $1785

1910.303 B02

Other-than-serious 1 instance 1 exposed
Issued
Jan 27, 2012
Abate by
Mar 30, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2):     Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    (a) In the storage area docks, a metal utility box powering an industrial fan was attached to a flexible pendant cord and freely suspended from a power source. The metal utility box was designed to be affixed to a wall surface.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View V & L Tool, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331073759.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.