MODESTO, CA ·
OSHA Inspection: CALIFORNIA ARMY NATIONAL GUARD FMS #27
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CALIFORNIA ARMY NATIONAL GUARD FMS #27 in 630 ROUSE AVENUE DRIVE FMS #27, MODESTO, CA 95351 (NAICS 928110). OSHA activity number 331074344.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CALIFORNIA ARMY NATIONAL GUARD FMS #27
- Site address
- 630 ROUSE AVENUE DRIVE FMS #27
- City
- MODESTO
- State
- CA
- ZIP
- 95351
- Mailing
- 630 ROUSE AVENUE DRIVE, MODESTO, CA 95351
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 928110
- Employees
- 8
- Ownership type
- Federal government (D)
Citations
6 citations on file for this inspection.
1910.157 B01
- Issued
- Nov 30, 2011
- Abate by
- Dec 21, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(b)(1): Where the employer has established and implemented a written fire safety policy which requires the immediate and total evacuation of employees from the workplace upon the sounding of a fire alarm signal and which includes an emergency action plan and a fire prevention plan which meet the requirements of 29 CFR 1910.38 and 29 CFR 1910.39 respectively, and when extinguishers are not available in the workplace, the employer is exempt from all requirements of this section unless a specific standard in part 1910 requires that a portable fire extinguisher be provided. a) Facility wide: On or about August 9, 2011, and at times prior thereto, the Emergency Action Plan and the Fire Evacuation Plan Maps posted did not show the current changes in the evacuation routes and reclassifications of Bays 1 thru Bay 6 in use.
Recent events (1)
- · Z (S) $0
1910.176 B
- Issued
- Nov 30, 2011
- Abate by
- Dec 21, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse: a) North Supply Room: On or about August 9, 2011, and at times prior thereto, the storage cabinet was not secured to the wall.
Recent events (1)
- · Z (S) $0
1910.178 L04 III
- Issued
- Nov 30, 2011
- Abate by
- Dec 21, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance shall be conducted at least once every three years. a) Facility - On or about August 9, 2011, and at times prior thereto, Bobcat operators did not have current training. The last equpment training was 3 August 2006 and expired in 2009. Operators were trained on different classes of equipment not currently used onsite.
Recent events (1)
- · Z (S) $0
1910.305 B01 II
- Issued
- Nov 30, 2011
- Abate by
- Dec 21, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) Northwest - Steam Cleaner Area: On August 9, 2011 , and at times prior thereto, a General Electric knife switch control box was missing a knockout on the underside which supplied power to the steam cleaner. b) North wall, Bay 2: On August 9, 2011 , and at times prior thereto, a General Electric knife switch control box was missing a knockout on the underside which supplied power to the Petroleum, Oil, and Lubricant area (POL). c) South, Tool Room: On August 9, 2011 , and at times prior thereto, a Square D Company safety knife switch control box was missing a knockout on the upper right side. d) West - Break room: On August 9, 2011 , and at times prior thereto, a 4 square mounted metal box was missing a knockout on the underside which supplied power to the microwave and coffee maker.
Recent events (1)
- · Z (S) $0
1910.305 G01 III
- Issued
- Nov 30, 2011
- Abate by
- Dec 21, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iii): Flexible cords and cables are prohibited as a substitute for fixed wiring. a) Southwest, Across from Bays 5 and 6: On or about August 9, 2011, and at times prior thereto, a flexible cord was used in place of fixed wiring running across the exit door to a nearby outlet creating an electrical and fire hazard.
Recent events (1)
- · Z (S) $0
1960.30 A
- Issued
- Nov 30, 2011
- Abate by
- Jan 13, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1960.30(a): The agency shall ensure the prompt abatement of unsafe and unhealthful conditions. Where a Notice of an Unsafe or Unhealthful Working Condition has been issued, abatement shall be within the time set forth in the notice, or in accordance with the established abatement plan. a) Facility - Main Shop Floor: On August 9, 2011 and at times prior thereto, the Vehicle exhaust system when used draws less than 7000 cfm for Bays 1 through Bay 4 creating a breathing hazard to floor mechanics and incidental personnel in the immediate area. This condition existed since 1996.
Recent events (1)
- · Z (S) $0
More inspections in this industry (NAICS 928110)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 331074344.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.