CENTERVILLE, OH ·
OSHA Inspection: DELORES GUERRERO
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DELORES GUERRERO in 7205 WHITETAIL, CENTERVILLE, OH 45440 (NAICS 238160). OSHA activity number 331074773.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DELORES GUERRERO
- Site address
- 7205 WHITETAIL
- City
- CENTERVILLE
- State
- OH
- ZIP
- 45440
- Mailing
- 9401 BARTLEY DR, LOUISVILLE, KY 40291
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 6
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1926.20 B02
- Issued
- Oct 28, 2011
- Penalty
- Initial $4,200 · Current $3,000 Reduced
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s) The employer did not ensure that frequent and regular inspections were conducted in that employees were exposed to safety and health hazards.
Recent events (2)
- · I (S) $3000
- · Z (S) $4200
1926.501 B13
- Issued
- Oct 28, 2011
- Penalty
- Initial $4,200 · Current $0 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502. Employees were engaged in a residential roofing operation and wearing harnesses but were exposed to a fall hazard in excess of 10 feet while not utilizing any type of anchor point.
Recent events (2)
- · I (S) $0
- · Z (S) $4200
More inspections in this industry (NAICS 238160)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 331074773.