Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,991Inspections Most recent open 2026-08-24 Last loaded 2026-08-27

OSHA Inspection: DEFENSE COMMISSARY AGENCY WEST REGION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DEFENSE COMMISSARY AGENCY WEST REGION in 20 HICKAM COURT BLDG. 2093, HICKAM AFB, HI 96853 (NAICS 445110). OSHA activity number 331075010.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Defense Commissary Agency West Region for free Get an email when a new federal OSHA severe-injury report for Defense Commissary Agency West Region is published. One employer, no account, unsubscribe in one click.
Site address
20 HICKAM COURT BLDG. 2093
City
HICKAM AFB
State
HI
ZIP
96853
Mailing
20 HICKAM COURT BLDG. 2093, HICKAM AFB, HI 96853
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
445110
Employees
101
Ownership type
Federal government (D)

2 citations on file for this inspection.

1910.178 G02

Serious Gravity 5 4 instances 10 exposed
Issued
Dec 22, 2011
Abate by
Feb 7, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.178(g)(2):     Battery charging apparatus for industrial trucks located in battery changing and charging installation was not protected from damage by trucks:    LOCATION: Warehouse (Back wall)    DESCRIPTION:  The warehouse facility did not provide for protecting charging apparatus from damage by trucks.
Recent events (1)
  • · Z (S) $0

1910.305 A02 IX

Serious Gravity 5 1 instance 10 exposed
Issued
Dec 22, 2011
Abate by
Dec 30, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.305(a)(2)(ix):     Lamps for general illumination were not protected from accidental contact or breakage by a suitable fixture or lampholder with a guard.    (a)  At warehouse bay #4, an articulating type lamp was exposed to physical damage.  The lamp was positioned approxmately 64" from the floor level and was not provided with an enclosure or guard to prevent damage, thus potentially exposing personnel to contact with a hot bulb or potential electrical shock.
Recent events (1)
  • · Z (S) $0

View Defense Commissary Agency West Region's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 331075010.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.