CHENOA, IL ·
OSHA Inspection: CHENOA WELDING & FABRICATION, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of CHENOA WELDING & FABRICATION, INC. in 322 MOREHEAD ST., CHENOA, IL 61726 (NAICS 332312). OSHA activity number 331075275.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CHENOA WELDING & FABRICATION, INC.
- Site address
- 322 MOREHEAD ST.
- City
- CHENOA
- State
- IL
- ZIP
- 61726
- Mailing
- 322 MOREHEAD ST., CHENOA, IL 61726
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 26
- Ownership type
- A
Citations
18 citations on file for this inspection.
1910.107 C06
- Issued
- Jan 19, 2012
- Abate by
- Feb 2, 2012
- Penalty
- Initial $2,800 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.107(c)(6): Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations: An employee within the paint building was exposed to fire hazards while performing painting operations. The electrical wiring in place was not explosion-proof in design and did not conform to the provisions of subpart S of this part for Class I, Division 1 Hazardous Locations.
Recent events (3)
- · C (S) $2800
- · F (S) $1000
- · Z (S) $2800
1910.134 C01
- Issued
- Jan 19, 2012
- Abate by
- Feb 2, 2012
- Penalty
- Initial $2,100 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: An employee was wearing a 3M half mask respirator while performing painting operations. The employer did not and implement and maintain a written respiratory protection program.
Recent events (3)
- · C (S) $2100
- · F (S) $1000
- · Z (S) $2100
1910.134 E01
- Issued
- Jan 19, 2012
- Abate by
- Feb 2, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employees ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: An employee was wearing a 3M half mask respirator while performing painting operations. The employer did not ensure that the employee had received a medical evaluation prior to use of the respirator in the workplace.
Recent events (3)
- · C (S) $0
- · F (S) $0
- · Z (S) $0
1910.134 F02
- Issued
- Jan 19, 2012
- Abate by
- Feb 2, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2): The employer did not ensure that an employee using a tight-fitting facepiece respirator was fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) is used, and at least annually thereafter. An employee was wearing a negative pressure half mask respirator while painting parts in the paint building and the employee had not been fit tested prior to intial use of the respirator.
Recent events (3)
- · C (S) $0
- · F (S) $0
- · Z (S) $0
1910.134 K05
- Issued
- Jan 19, 2012
- Abate by
- Feb 2, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k)(5): Respiratory protection retraining was not conducted annually: An employee was wearing a 3M half mask respirator while performing painting operations. The employer did not provide annual respiratory protection training.
Recent events (3)
- · C (S) $0
- · F (S) $0
- · Z (S) $0
1910.178 L04 III
- Issued
- Jan 19, 2012
- Abate by
- Jan 26, 2012
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operators performance was not conducted at least once every 3 years. Employees were operating forklifts while moving parts. An evaluation of each powered industrial truck operators performance had not been conducted at least once every 3 years.
Recent events (3)
- · C (S) $2800
- · F (O) $0
- · Z (S) $2800
1910.178 L06
- Issued
- Jan 19, 2012
- Abate by
- Jan 26, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator had been trained and evaluated as required by this paragraph (l) Employees were operating forklifts while moving parts. The employer failed to certify that each operator had been trained and evaluated in the operation of the forklifts.
Recent events (3)
- · C (S) $0
- · F (O) $0
- · Z (S) $0
1910.303 B02
- Issued
- Jan 19, 2012
- Abate by
- Jan 26, 2012
- Penalty
- Initial $2,800 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: Employees were exposed to electrical hazards while working around live extension cords which were outfitted with metal electrical boxes. The boxes contained knockouts and were intended to be mounted on a wall.
Recent events (3)
- · C (S) $2800
- · F (S) $1000
- · Z (S) $2800
1910.303 G02 I
- Issued
- Jan 19, 2012
- Abate by
- Jan 26, 2012
- Penalty
- Initial $4,200 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): An employee was exposed to electrical hazards from live 110 volt wiring which terminated near the door. The live ends were not guarded against accidental contact by use of enclosure.
Recent events (3)
- · C (S) $4200
- · F (S) $1000
- · Z (S) $4200
1910.305 B01 II
- Issued
- Jan 19, 2012
- Abate by
- Jan 26, 2012
- Penalty
- Initial $3,500 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: Employees working within bay one were exposed to electrical hazards. Two electrical panels had multiple missing blanks and were not effectively closed to prevent contact with energized parts.
Recent events (3)
- · C (S) $3500
- · F (S) $1000
- · Z (S) $3500
1910.1026 D02 I
- Issued
- Jan 19, 2012
- Abate by
- Feb 2, 2012
- Penalty
- Initial $3,500 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.1026(d)(2)(i): The employer using the scheduled monitoring option did not perform initial monitoring to determine the 8-hour time-weighted average exposure to chromium (VI) for each employee on the basis of a sufficient number of personal breathing zone air samples to accurately characterize full shift exposure on each shift, for each job classification, in each work area: Employees were potentially exposed to hexavelant chromium while welding on stainless steel. The employer failed to perform initial monitoring.
Recent events (3)
- · C (S) $3500
- · F (S) $1000
- · Z (S) $3500
1910.1200 G08
- Issued
- Jan 19, 2012
- Abate by
- Jan 26, 2012
- Penalty
- Initial $3,500 · Current $0 Reduced
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not maintain copies of the required material safety data sheets for each hazardous chemical in the workplace: Employees were exposed to the physical and chemical hazards associated with welding fumes from stainless steel and structural steel; as well as vapors from various paints. Employees were not provided information and training as required on hazardous chemicals in their work areas. The employer did not maintain material safety data sheets for each hazardous chemical in the workplace.
Recent events (3)
- · C (S) $3500
- · F (S) $0
- · Z (S) $3500
1910.106 D04 I
- Issued
- Jan 19, 2012
- Abate by
- Feb 9, 2012
- Penalty
- Initial $2,800 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.106(d)(4)(i): Inside storage rooms were not constructed to meet the test specifications set forth in the Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. An employee working within the paint building was exposed to potential fire hazards because the inside storage room within the building did not have an approved fire rating nor was it liquid tight in construction. Additionally the inside storage room did not have a raised sill and was not equipped with a self-closing fire door.
Recent events (3)
- · C (S) $2800
- · F (S) $1000
- · Z (S) $2800
1910.107 C07
- Issued
- Jan 19, 2012
- Abate by
- Feb 2, 2012
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.107(c)(7): Electric lamps outside of but within 20 feet of spraying area(s), and not separated there from by partition(s), were not protected from mechanical injury by suitable guards or by location: An employee within the paint building was exposed to fire hazards while performing painting operations. The lights in place on the East and West walls were not protected by suitable guards to prevent against breakage.
Recent events (3)
- · C (S) $2800
- · F (S) $0
- · Z (S) $2800
1910.1200 E01
- Issued
- Jan 19, 2012
- Abate by
- Feb 2, 2012
- Penalty
- Initial $3,500 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): Employees performed welding on structural and stainless steel and used various paints including Sherman-Williams Shopcoat Primer. The employer did not implement and maintain a written hazard communication program.
Recent events (3)
- · C (S) $3500
- · F (S) $1000
- · Z (S) $3500
1910.1200 F05 I
- Issued
- Jan 19, 2012
- Abate by
- Jan 26, 2012
- Penalty
- Initial $2,100 · Current $0 Reduced
General-duty citation text
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein: A container of paint was used by an employee within the paint building. The container was not labeled, tagged, or marked with the identity of the hazardous chemicals contained therein.
Recent events (3)
- · C (S) $2100
- · F (S) $0
- · Z (S) $2100
1910.1200 F05 II
- Issued
- Jan 19, 2012
- Abate by
- Jan 26, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings: A container of paint was used by an employee within the paint building. The container was not labeled, tagged or marked with the hazards associated with the substance. The container was no labeled to convey general information regarding the product's hazards.
Recent events (3)
- · C (S) $0
- · F (S) $0
- · Z (S) $0
1910.1200 H01
- Issued
- Jan 19, 2012
- Abate by
- Feb 2, 2012
- Penalty
- Initial $3,500 · Current $0 Reduced
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: Employees were exposed to the physical and chemical hazards associated with welding fumes from stainless steel and structural steel; as well as vapors from various paints. Employees were not provided information and training as required on hazardous chemicals in their work areas.
Recent events (3)
- · C (S) $3500
- · F (S) $0
- · Z (S) $3500
More inspections in this industry (NAICS 332312)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331075275.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.