Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ACCURATE FAB

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ACCURATE FAB in 1430 MILLER PARKWAY, STREETSBORO, OH 44241 (NAICS 332312). OSHA activity number 331075739.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Accurate FAB — free Get an email when a new federal OSHA severe-injury report for Accurate FAB is published. One employer, no account, unsubscribe in one click.
Establishment
ACCURATE FAB
Site address
1430 MILLER PARKWAY
City
STREETSBORO
State
OH
ZIP
44241
Mailing
1430 MILLER PARKWAY, STREETSBORO, OH 44241
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
7
Ownership type
A

6 citations on file for this inspection.

1910.303 F

Serious Gravity 1 1 instance 2 exposed
Issued
Nov 16, 2011
Abate by
Nov 30, 2011
Penalty
Initial $1,800 · Current $1,000 Reduced
29 CFR 1910.303(f):     Each service, feeder and branch circuit, at its disconnecting means or over current device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:    By the exit door, the panel box containing the disconnects for the lights, transformers and other equipment, was not labeled.
Recent events (3)
  • — F (S) $1000
  • — C (S) $1800
  • — Z (S) $1800

1910.303 G01

Serious Gravity 1 1 instance 1 exposed
Issued
Nov 16, 2011
Abate by
Nov 19, 2011
Penalty
Initial $1,800 · Current $1,000 Reduced
29 CFR 1910.303(g)(1):     Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:    The 480V panel box by the exit door, was blocked by wood.
Recent events (3)
  • — F (S) $1000
  • — C (S) $1800
  • — Z (S) $1800

1910.212 A03 II

Willful Gravity 10 1 instance 1 exposed
Issued
Nov 16, 2011
Abate by
Nov 30, 2011
Penalty
Initial $14,000 · Current $7,000 Reduced
29 CFR 1910.212(a)(3)(ii):     Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    The Trauma Bend C120 press brake, operated by foot, did not have any point of operation guarding.
Recent events (3)
  • — F (W) $7000
  • — C (W) $14000
  • — Z (W) $14000

1910.147 A02 II

Repeat Gravity 5 1 instance 1 exposed
Issued
Nov 16, 2011
Abate by
Nov 23, 2011
Penalty
Initial $7,200 · Current $3,000 Reduced
29 CFR 1910.147(a)(2)(ii):     Lockout/tagout procedures are to be implemented when servicing and/or maintenance is taking place during normal production operations if an employee is required to (A) Remove or bypass a guard or other safety device; (B) is required to place any part of his or her body into area on a machine or piece of equipment where work is actually performed upon the material being processed (point of operation) or where an associated danger zone exists during a machine operating cycle:    On or before10/13/11, employees who are required to do set-up /maintenance on the hydraulic press brake, did not lockout the hydraulic press brake.    NOTE:  ACCURATE FAB WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 1910.147(c)(1), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 314382276, CITATION NUMBER 1, ITEM NUMBER 3, AND WAS AFFIRMED AS A FINAL ORDER ON 5/10/10, WITH RESPECT TO A WORKPLACE AT 1430 MILLER PARKWAY, STREETSBORO, OHIO.
Recent events (3)
  • — F (R) $3000
  • — C (R) $7200
  • — Z (R) $7200

1910.147 C07 I A

Repeat Gravity 5 1 instance 1 exposed
Issued
Nov 16, 2011
Abate by
Nov 30, 2011
Penalty
Initial $7,200 · Current $3,000 Reduced
29 CFR 1910.147(c)(7)(i)(A):     Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control:    Authorized employees did not receive training in the recognition of hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.  Equipment includes, but is not limited to, hydraulic press brakes,  etc.    NOTE:  ACCURATE FAB WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 1910.147(c)(1), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 314382276, CITATION NUMBER 1, ITEM NUMBER 3, AND WAS AFFIRMED AS A FINAL ORDER ON 5/10/10, WITH RESPECT TO A WORKPLACE AT 1430 MILLER PARKWAY, STREETSBORO, OHIO.
Recent events (3)
  • — F (R) $3000
  • — C (R) $7200
  • — Z (R) $7200

1910.147 D04 I

Repeat Gravity 5 1 instance 1 exposed
Issued
Nov 16, 2011
Abate by
Nov 30, 2011
Penalty
Initial $7,200 · Current $3,000 Reduced
29 CFR 1910.147(d)(4)(i):     Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:    On or before 10/13/11, employees who are requried to do maintenance  and/or servicing on the hydraulic press brake, did not lockout the machine prior to doing any maintenance and/or servicing.    NOTE:  ACCURATE FAB WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 1910.147(c)(1), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 314382276, CITATION NUMBER 1, ITEM NUMBER 3, AND WAS AFFIRMED AS A FINAL ORDER ON 5/10/10, WITH RESPECT TO A WORKPLACE AT 1430 MILLER PARKWAY, STREETSBORO, OHIO.
Recent events (3)
  • — F (R) $3000
  • — C (R) $7200
  • — Z (R) $7200

View Accurate FAB's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331075739.