OSHA Inspection: RICK'S ROOFING

Programmed Related inspection · Safety discipline

On , OSHA opened a programmed Related safety inspection of RICK'S ROOFING in 3730 PICKLE RD., OREGON, OH 43616 (NAICS 238160). OSHA activity number 331076505.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Rick'S Roofing — free Get an email when a new federal OSHA severe-injury report for Rick'S Roofing is published. One employer, no account, unsubscribe in one click.
Establishment
RICK'S ROOFING
Site address
3730 PICKLE RD.
City
OREGON
State
OH
ZIP
43616
Mailing
164 E. MADISON, PETERSBURG, MI 49270
Inspection type
Programmed Related (J)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
6
Ownership type
A

3 citations on file for this inspection.

1926.501 B04 II

Serious Gravity 5 1 instance 5 exposed
Issued
Dec 7, 2011
Abate by
Dec 14, 2011
Penalty
Initial $2,640 · Current $924 Reduced
29 CFR 1926.501(b)(4)(ii): Each employee on a walking/working surface was not protected from tripping in or stepping into or through holes (including skylights) by covers.    a. Rick's Roofing work site located at 3730 Pickle Rd., Oregon, Ohio:  On or about October 13, 2011, the employer did not ensure employees were protected from falling through a skylight while performing roof tear off operations on a single story residential building.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records
Recent events (2)
  • — I (S) $924
  • — Z (S) $2640

1926.1053 B01

Serious Gravity 5 1 instance 7 exposed
Issued
Dec 7, 2011
Abate by
Dec 14, 2011
Penalty
Initial $2,640 · Current $924 Reduced
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails were not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder was not secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder.  In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.    a. Rick's Roofing work site located at 3730 Pickle Rd., Oregon, Ohio:  On or about October 13, 2011, the employer did not ensure the aluminum extension ladder used by employees to access the roof was extended three feet above the working surface of the roof.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records
Recent events (2)
  • — I (S) $924
  • — Z (S) $2640

1926.501 B13

Repeat Gravity 5 1 instance 7 exposed
Issued
Dec 7, 2011
Abate by
Dec 14, 2011
Penalty
Initial $5,280 · Current $1,848 Reduced
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet(1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.    a. Ricks Roofing work site located at 3730 Pickle Rd., Oregon, Ohio:  On or about October 13, 2011, the employer did not ensure employees performing a roof tear off operation on a one story residential structure were protected from falling approximately 10 feet to the ground.     Rick's roofing was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA Inspection Number 92493, citation number 1, item number 1 and was affirmed as a final order on August 16, 2011, with respect to a workplace located at 3112 Turnberry Drive, Findlay, Ohio.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • — I (R) $1848
  • — Z (R) $5280

View Rick'S Roofing's full OSHA safety record →