COEUR D ALENE, ID ·
OSHA Inspection: SCHUON MANUFACTURING CO INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SCHUON MANUFACTURING CO INC in 5889 NORTH ENGINEER STREET, COEUR D ALENE, ID 83815 (NAICS 333210). OSHA activity number 331076927.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SCHUON MANUFACTURING CO INC
- Site address
- 5889 NORTH ENGINEER STREET
- City
- COEUR D ALENE
- State
- ID
- ZIP
- 83815
- Mailing
- P O BOX 1565, HAYDEN, ID 83835
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333210
- Employees
- 38
- Ownership type
- A
Citations
15 citations on file for this inspection.
1910.95 G01
- Issued
- Feb 22, 2012
- Abate by
- Mar 14, 2012
- Penalty
- Initial $2,380 · Current $1,190 Reduced
General-duty citation text
29 CFR 1910.95(g)(1): The employer did not establish and maintain an audiometric testing program as provided by 29 CFR 1910.95(g) by making audiometric testing available to all employees whose exposures equal or exceed an 8-hour time-weighted average of 85 decibels: a) Where fabricators were exposed up to 92.4 decibels, as documented in the industrial hygiene report of August 20, 2009 and confirmed with sound level measurements on October 4, 2011. Audiometric testing was not conducted. Abatement Note: A hearing conservation program includes, but is not limited to, noise monitoring, audiograms (initial and annual), and training on the types and use of hearing protection. Note: Abatement certification is required for this item.
Recent events (2)
- · I (S) $1190
- · Z (S) $2380
1910.107 C02
- Issued
- Feb 22, 2012
- Abate by
- Apr 4, 2012
- Penalty
- Initial $2,380 · Current $1,190 Reduced
General-duty citation text
29 CFR 1910.107(c)(2): Open flame(s) or spark producing equipment, not separated by a partition, were located within 20 feet of spraying area(s): a) Fabrication areas; On or about 10/3/2011 and at times prior thereto, welding and pre-heating operations were located within five feet of the paint spraying area. Note: Abatement certification is required for this item
Recent events (2)
- · I (S) $1190
- · Z (S) $2380
1910.107 C06
- Issued
- Feb 22, 2012
- Abate by
- Apr 4, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(c)(6): Electrical wiring and equipment outside of but within 20 feet of spraying area(s), and not separated therefrom by partitions, did not conform to the provisions for Class I, Division 2, hazardous locations: a) Fabrication areas; On or about 10/3/2011 and at times prior thereto, electrical equipment including, but not limited to, electrical outlets, lights and electrical switch were immediately adjacent to the paint spraying area. Note: Abatement certification is required for this item
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.107 D04
- Issued
- Feb 22, 2012
- Abate by
- Apr 4, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(d)(4): The fan-rotating element(s) was not of nonferrous or nonsparking material: a) Paint Spraying Area; On or about 10/3/2011 and at times prior thereto, three steel blade ventilation exhaust fans were mounted on the wall of the spraying area. Note: Abatement certification is required for this item.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.147 C04 I
- Issued
- Feb 22, 2012
- Abate by
- Apr 4, 2012
- Penalty
- Initial $2,380 · Current $1,190 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) All areas; On or about 10/3/2011 and at times prior thereto, employees at the facility were servicing and maintaining cranes, angle machine, plate machine, conveyors and other machines and equipment without specific lockout/tagout procedures being established and implemented for that equipment. Note: Abatement certification is required for this item
Recent events (2)
- · I (S) $1190
- · Z (S) $2380
1910.178 L01 II
- Issued
- Feb 22, 2012
- Abate by
- Apr 4, 2012
- Penalty
- Initial $2,380 · Current $1,190 Reduced
General-duty citation text
29 CFR1910.178(l)(1)(ii): Prior to permitting an employee to operate a powered industrial truck (except for training purposes), the employer did not ensure that each operator has successfully completed the training required by this paragraph (l), except as permitted by paragraph (l)(5): a) Establishment; On or about 10/3/2011 and at times prior thereto, employees were not provide with training prior to being allowed to operate forklifts within the facility. Note: Abatement certification is required for this item
Recent events (2)
- · I (S) $1190
- · Z (S) $2380
1910.178 L06
- Issued
- Feb 22, 2012
- Abate by
- Apr 4, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l). The certification did not include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation: a) Establishment; On or about 10/3/2011 and at times prior thereto, the employer did not have/could not provide certification for employees that were operating forklifts at the facility. Note: Abatement certification is required for this item.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.178 P01
- Issued
- Feb 22, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(p)(1): A powered industrial truck in need of repair was not taken out of service until it has been restored to safe operating condition: a) Establishment; On or about 10/3/2011 and at times prior thereto, an 8,000 pound capacity Clark forklift with an excessive hydraulic fluid leak on the master hydraulic cylinder had not been taken out of service. Note: Abatement certification is not required for this item
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.212 A01
- Issued
- Feb 22, 2012
- Abate by
- Mar 14, 2012
- Penalty
- Initial $2,380 · Current $1,190 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) In-feed to Python and Roller Conveyor to Plate Machine: Employees using the adjacent walkway and work area were exposed to the rollers and other rotating parts. b) Out-feed to Python Roller Conveyor: Employees using the adjacent walkway and work area were exposed to the rollers. NOTE: Abatement certification is required for this item.
Recent events (2)
- · I (S) $1190
- · Z (S) $2380
1910.219 C04 I
- Issued
- Feb 22, 2012
- Abate by
- Apr 4, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one-half the diameter of the shaft: a) Python Out Feed Roller Conveyor: The roller shafts were 1-7/16th of an inch in diameter and the shaft-end projected 3-1/4 inches. Note: Abatement certification is required for this item
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.219 I02
- Issued
- Feb 22, 2012
- Abate by
- Apr 4, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(i)(2): Bolt(s), nuts, or setscrews used in shaft coupling(s) extended beyond the flange of the coupling and were not covered with safety sleeve(s): a) Infeed to Python conveying system: A driving shaft split coupling was not enclosed or equipped with a safety barrier to prevent inadvertent physical contact. Note: Abatement certification is required for this item
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.106 E02 III
- Issued
- Feb 22, 2012
- Abate by
- Apr 4, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(e)(2)(iii): Adequate natural or mechanical ventilation was not provided in area(s) where flammable or combustible liquids were transferred: a) Outside Paint storage building: Approximately 25 gallons of paint, primer, thinner and ten gallons of gasoline were stored in the unventilated building. Note: Abatement certification is required for this item
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.134 E01
- Issued
- Feb 22, 2012
- Abate by
- Apr 4, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employees ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) Paint Area; On or about 10/3/2011 and at times prior thereto, an employee was using a half-face-piece respirator without having had a medical evaluation. Note: Abatement certification is required for this item
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.134 F02
- Issued
- Feb 22, 2012
- Abate by
- Apr 4, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2): The employer did not ensure that an employee using a tight-fitting facepiece respirator was fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) was used, and at least annually thereafter: a) Paint Area; On or about 10/3/2011 and at times prior thereto, an employee was using a tight-fitting half-face-piece respirator without having been fit tested. Note: Abatement certification is required for this item.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.254 D09 III
- Issued
- Feb 22, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.254(d)(9)(iii): Cables with damaged insulation or exposed bare conductors were not replaced: a) North Welding Area, 60-Foot Bay, Miller Welder #12: The protectuve coating on the cable for the wire feed MIG welder was damaged in several locations. Note: Abatement certification or documentation is NOT required for this item
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 333210)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331076927.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.