OSHA Inspection: RICHARD HART CONSTRUCTION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RICHARD HART CONSTRUCTION, INC. in 1602 E LADY BUG LN., HAYDEN, ID 83835 (NAICS 238130). OSHA activity number 331077107.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Richard Hart Construction, INC. — free Get an email when a new federal OSHA severe-injury report for Richard Hart Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1602 E LADY BUG LN.
City
HAYDEN
State
ID
ZIP
83835
Mailing
P.O. BOX 823, RATHDRUM, ID 83858
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
3
Ownership type
A

4 citations on file for this inspection.

1926.403 B01

Serious Gravity 1 1 instance 3 exposed
Issued
Nov 15, 2011
Penalty
Initial $1,300 · Current $650 Reduced
29 CFR 1926.403(b)(1): Employer did not ensure that electric equipment was free from recognized hazards that were likely to cause death or serious physical harm to employees:    a)  At the job site, the 110 VAC metallic electric outlet junction box, intended for wall installation, was used outdoors on cords in a portable form and was damaged and repaired with duct tape, thereby exposing employees to potential electric shock.      Abatement certification is NOT required for this item
Recent events (2)
  • — I (S) $650
  • — Z (S) $1300

1926.404 B01 II

Serious Gravity 1 1 instance 3 exposed
Issued
Nov 15, 2011
Penalty
Initial $0 · Current $0
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120 volt, singlep hase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which were used by employees did not have approved groundfault circuit interrupters for personnel protection:    a) At the temporary electrical panel, the electric outlet was equipped with an inoperable ground fault circuit interrupter.  It was used by employees to energize the portable outlet junction box that powered skil saws exposing employees to the hazard of electric shock.    Abatement certification is NOT required for this item
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.404 F07 IV C

Serious Gravity 1 1 instance 3 exposed
Issued
Nov 15, 2011
Penalty
Initial $0 · Current $0
29 CFR 1926.404(f)(7)(iv)(C): Exposed noncurrent-carrying metal parts of cord- and plug-connected equipment which could become energized were not grounded when the equipment was one of the types listed in 29 CFR 1926.404(f)(7)(iv)(C) (1) through (5):     a) At the residential construction site, the ground pin was missing on the electrical cord for the skil saw.  The hand-held motor-operated skil saw was not grounded exposing employees to the hazard of electric shock.    Abatement certification is NOT required for this item
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.405 A02 II E

Serious Gravity 1 1 instance 3 exposed
Issued
Nov 15, 2011
Penalty
Initial $0 · Current $0
29 CFR 1926.405(a)(2)(ii)(E): Lamps used in temporary wiring for general illumination were not protected from accidental contact or breakage:     a) At the detached frame structure, the incandescent light bulb that was used for temporary lighting, was not equipped with a safety guard.    Abatement certification is NOT required for this item
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331077107.