KENT, OH ·
OSHA Inspection: MAC LTT, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MAC LTT, INC. in 1400 FAIRCHILD AVE., KENT, OH 44240 (NAICS 336212). OSHA activity number 331078063.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MAC LTT, INC.
- Site address
- 1400 FAIRCHILD AVE.
- City
- KENT
- State
- OH
- ZIP
- 44240
- Mailing
- 1400 FAIRCHILD AVE., KENT, OH 44240
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336212
- Employees
- 40
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1910.157 G02
- Issued
- Feb 21, 2012
- Abate by
- Apr 23, 2012
- Penalty
- Initial $2,100 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter: The employer did not train employees on the use of portable fire extinguishers for those employees expected to fight incipient stage fires. NOTE: The employer may exercise one of the following options: 1) Provide portable fire extinguishers as specified in 29 CFR 1910.157(c)(1), meet the distribution requirements per 29 CFR 1910.157(d) (75 to the nearest extinguisher for Class A fires and 50 to the nearest extinguisher for Class B fires), and provide training and education for all employees in the use of such equipment and the hazards associated with incipient stage fire fighting as required in 29 CFR 1910.157(g). The other sections of 29 CFR 1910.157 also apply. 2) Provide extinguishers as specified in 29 CFR 1910.157(c) (1), designate certain employees to be the only employees authorized to use such equipment and require all other employees to immediately evacuate upon the sounding of the fire alarm, establish this in writing in an emergency action plan as outlined in 29 CFR 1910.38(c) and train/educate designated employees per 1910.157(g). Utilizing this option exempts the employer from distribution requirements of 29 CFR 1910.157(d). 3) Establish a written fire safety policy which requires the immediate and total evacuation of employees from the workplace upon the sounding of a fire alarm signal. This policy includes an emergency action plan and a fire prevention plan as specified in 29 CFR 1910.38(a) and (b). Utilizing this option exempts the employer from the requirements of 1910.157 to include the need for providing portable fire equipment unless a specific standard requires that a portable fire extinguisher be provided (such as those requirements in 29 CFR 1910.106/107 relating to use/storage of flammable/combustible liquids). If extinguishers are provided but not intended for employee use, 29 CFR 1910.157(a) and (f) are still applicable (inspection, maintenance and testing of equipment).
Recent events (2)
- · I (S) $1260
- · Z (S) $2100
1910.178 L01 II
- Issued
- Feb 21, 2012
- Abate by
- Mar 6, 2012
- Penalty
- Initial $2,100 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(ii): The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to truck operation: On or before 10/17/11, the employer allowed forklift operators to operate a forklift without observing them in the workplace.
Recent events (2)
- · I (S) $1260
- · Z (S) $2100
1910.304 F
- Issued
- Feb 21, 2012
- Abate by
- Feb 24, 2012
- Penalty
- Initial $2,100 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.304(f)(5): The path to ground from circuits, equipment, and enclosures shall be permanent, continuous, and effective: The grounding pin was broken for the floor fan used at the facility.
Recent events (2)
- · I (S) $1260
- · Z (S) $2100
1910.305 G02 III
- Issued
- Feb 21, 2012
- Abate by
- Feb 24, 2012
- Penalty
- Initial $2,100 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: The plasma cuter did not have any strain relief provided.
Recent events (2)
- · I (S) $1260
- · Z (S) $2100
More inspections at MAC LTT, INC.
View MAC LTT, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 336212)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 331078063.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.