MALVERN, OH —
OSHA Inspection: COLFOR MANUFACTURING, INC.
Follow-up inspection · Safety discipline
At a glance
On , OSHA opened a follow-up safety inspection of COLFOR MANUFACTURING, INC. in 3255 ALLIANCE ROAD N.W., MALVERN, OH 44644 (NAICS 332111). OSHA activity number 331078972.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COLFOR MANUFACTURING, INC.
- Site address
- 3255 ALLIANCE ROAD N.W.
- City
- MALVERN
- State
- OH
- ZIP
- 44644
- Mailing
- 3255 ALLIANCE ROAD, MALVERN, OH 44644
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332111
- Employees
- 245
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C04 II B
- Issued
- Dec 5, 2011
- Abate by
- Nov 26, 2012
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following: Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy; In the workplace, the employer's energy control procedure for the Ajax 747 mechanical forging press did not address, nor demonstrate specific methods to control hazardous hydraulic energy.
Recent events (3)
- — F (S) $7000
- — C (S) $7000
- — Z (S) $7000
1910.147 C04 II C
- Issued
- Dec 5, 2011
- Abate by
- Nov 26, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(C): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following: Specific procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them: In the workplace, the hazardous energy control procedure for the Ajax Mechanical Forging Press 747 did not specify steps or methods for placing locks on the energy isolation device(s).
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.147 C06 I
- Issued
- Dec 5, 2011
- Abate by
- Nov 26, 2011
- Penalty
- Initial $5,500 · Current $7,000
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. In the workplace, the employer had not performed an adequate inspection of the energy control procedures such as, but not limited to, the Ajax Forging Press 747 at least annually.
Recent events (3)
- — F (S) $7000
- — C (S) $5500
- — Z (S) $5500
1910.218 F01 I
- Issued
- Dec 5, 2011
- Abate by
- Nov 26, 2011
- Penalty
- Initial $38,500 · Current $7,000 Reduced
General-duty citation text
29 CFR 1910.218(f)(1)(i): Mechanical forging presses. When dies are being changed or maintenance is being performed on the press, the following shall be accomplished: The power to the press shall be locked out. In the workplace, the employer did not require the Ajax Mechanical Forging Press 747 to be de-energized and locked out during cleaning and knockout pin repair/replacement where employees were working between the press bolsters of an energized press. Colfor Manufacturing, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.218(f)(1)(i), which was contained in OSHA inspection number 313153256, citation number 01, item number 01a and was affirmed as a final order on March 15, 2010, with respect to a workplace located at 3255 Alliance Rd. NW, Malvern, OH. 44644.
Recent events (3)
- — F (S) $7000
- — C (R) $38500
- — Z (R) $38500
More inspections at Colfor Manufacturing, INC.
View Colfor Manufacturing, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332111)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331078972.