SAINT CHARLES, IL —
OSHA Inspection: GLENBROOK EXCAVATING AND CONCRETE, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of GLENBROOK EXCAVATING AND CONCRETE, INC. in N 9TH AVE & CEDAR AVENUE N OF RR TRACKS, SAINT CHARLES, IL 60174 (NAICS 237110). OSHA activity number 331079798.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GLENBROOK EXCAVATING AND CONCRETE, INC.
- Site address
- N 9TH AVE & CEDAR AVENUE N OF RR TRACKS
- City
- SAINT CHARLES
- State
- IL
- ZIP
- 60174
- Mailing
- 1350 N OLD RANDALL RD, WAUCONDA, IL 60084
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- Employees
- 5
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.100 A
- Issued
- Nov 30, 2011
- Abate by
- Dec 7, 2011
- Penalty
- Initial $3,300 · Current $0 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: On or about October 20, 2011 employees were working below shovels, gravel, rocks, and an operating backhoe without hardhats exposing the employees to overhead struckby hazards. Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c)
Recent events (4)
- — W (S) $3300
- — F (S) $0
- — C (S) $3300
1926.651 C02
- Issued
- Nov 30, 2011
- Abate by
- Dec 7, 2011
- Penalty
- Initial $3,300 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: On or about October 20, 2011 an employee was working in a trench at a depth greater than 4 feet laboring to find a leak in a water main between a storm sewer and teh backhoe without a safe means of egress exposing the employee to being unable to exit the trench in a trench in an emergency. Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c)
Recent events (4)
- — F (S) $3300
- — F (O) $1000
- — C (S) $3300
1926.651 I03
- Issued
- Nov 30, 2011
- Abate by
- Dec 7, 2011
- Penalty
- Initial $2,640 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.651(i)(3): Sidewalks, pavements, or appurtenant structures had been undermined and a support system or another method was not provided to protect employees from the possible collapse of such structures: On or about October 20, 2011 employees were working in a trench laboring to find a leak in a water main with an undercut portion of the street was not supported exposing employees to a struckby hazard. Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c)
Recent events (4)
- — F (S) $2640
- — F (O) $1000
- — C (S) $2640
1926.651 J02
- Issued
- Nov 30, 2011
- Abate by
- Dec 7, 2011
- Penalty
- Initial $2,640 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary. On or about October 20, 2011 employees were working in a trench laboring to find a leak in a water main with fill material rocks, gravel, and a shovel located within two (2) feet of the edge of the trench exposing the employees to struckby hazards. Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c)
Recent events (4)
- — F (S) $2640
- — F (S) $1000
- — C (S) $2640
1926.651 K02
- Issued
- Nov 30, 2011
- Abate by
- Dec 7, 2011
- Penalty
- Initial $3,300 · Current $0 Reduced
General-duty citation text
29 CFR 1926.651(k)(2): Where the competent person found evidence of a situation that could result in possible cave-in, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions, exposed employee(s) was/were not removed from the hazardous area until the necessary precautions have been taken to ensure their safety. On or about October 20, 2011 employees were working in a trench laboring to find a leak in a water main where the competent person saw evidence of hazardous conditions exposing employees to the hazards associated with a trench collapse. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d)
Recent events (4)
- — W (S) $3300
- — F (S) $0
- — C (S) $3300
1926.651 K01
- Issued
- Nov 30, 2011
- Abate by
- Dec 7, 2011
- Penalty
- Initial $9,240 · Current $3,000 Reduced
General-duty citation text
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated. On or about October 20, 2011, the employer did not ensure that the competent person examined the excavation prior to employees entering the excavation to look for a leak in a water main. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d)
Recent events (3)
- — F (S) $3000
- — C (R) $9240
- — Z (R) $9240
More inspections at Glenbrook Excavating and Concrete, INC.
View Glenbrook Excavating and Concrete, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 237110)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331079798.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.