Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,195,903Inspections Most recent open 2026-08-18 Last loaded 2026-08-21

OSHA Inspection: QUALITY CASTINGS

Fatality or catastrophe inspection · Safety discipline

On , OSHA opened a fatality or catastrophe safety inspection of QUALITY CASTINGS in 1200 N. MAIN STREET, ORRVILLE, OH 44667 (NAICS 331511). OSHA activity number 331080994.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Quality Castings for free Get an email when a new federal OSHA severe-injury report for Quality Castings is published. One employer, no account, unsubscribe in one click.
Establishment
QUALITY CASTINGS
Site address
1200 N. MAIN STREET
City
ORRVILLE
State
OH
ZIP
44667
Mailing
1200 N. MAIN STREET, ORRVILLE, OH 44667
Inspection type
Fatality or catastrophe (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331511
Employees
370
Ownership type
Private (A)

4 citations on file for this inspection.

1910.147 D04 I

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 29, 2012
Penalty
Initial $38,500 · Current $5,775 Reduced
29 CFR 1910.147(d)(4)(i):     Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:    On or before 10/19/11, an employee who was doing servicing/maintenance on the south wheelabrator (small) did not lock out the machine prior to doing any servicing/maintenance of the equipment.    NOTE:  QUALITY CASTINGS COMPANY, WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD, OR ITS EQUIVALENT STANDARD 1910.147(d)(4)(i), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 314382557, CITATION NUMBER 1, ITEM NUMBER 5(b), AND WAS AFFIRMED AS A FINAL ORDER ON 10/22/10, WITH RESPECT TO A WORKPLACE AT 1200 N. MAIN STREET, ORRVILLE, OHIO.
Recent events (4)
  • · F (S) $5775
  • · F (S) $5775
  • · C (R) $38500

1910.147 C04 I

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 29, 2012
Abate by
Jun 3, 2013
Penalty
Initial $5,775 · Current $5,775
29 CFR 1910.147(c)(4)(i):     Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:    On or before 10/19/11, an employee who was doing servicing/maintenance on the south wheelabrator (small) did not lock out the machine prior to doing any servicing/maintenance of the equipment.    NOTE:  QUALITY CASTINGS COMPANY, WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD, OR ITS EQUIVALENT STANDARD 1910.147(d)(4)(i), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 314382557, CITATION NUMBER 1, ITEM NUMBER 5(b), AND WAS AFFIRMED AS A FINAL ORDER ON 10/22/10, WITH RESPECT TO A WORKPLACE AT 1200 N. MAIN STREET, ORRVILLE, OHIO
Recent events (4)
  • · F (S) $5775
  • · F (S) $5775
  • · C (S) $5775

1910.147 C07 I A

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 29, 2012
Abate by
Apr 1, 2013
Penalty
Initial $5,775 · Current $5,775
29 CFR 1910.147(c)(7)(i)(A):  Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of energy available in the workplace, and the methods and means necessary for energy iolation and control:    Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:    On or before 10/19/11, an employee who was doing servicing/maintenance on the south wheelabrator (small) did not lock out the machine prior to doing any servicing/maintenance of the equipment.    NOTE:  QUALITY CASTINGS COMPANY, WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD, OR ITS EQUIVALENT STANDARD 1910.147(d)(4)(i), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 314382557, CITATION NUMBER 1, ITEM NUMBER 5(b), AND WAS AFFIRMED AS A FINAL ORDER ON 10/22/10, WITH RESPECT TO A WORKPLACE AT 1200 N. MAIN STREET, ORRVILLE, OHIO
Recent events (4)
  • · F (S) $5775
  • · F (S) $5775
  • · C (S) $5775

1910.147 D03

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 29, 2012
Abate by
Jun 3, 2013
Penalty
Initial $5,775 · Current $5,775
29 CFR 1910.147(d)(3):     All energy isolating devices that were needed to control the energy to the machine or equipment shall be physically located and operated in such a manner as to isolate the machine or equipment  from the energy source(s):    Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:    On or before 10/19/11, an employee who was doing servicing/maintenance on the south wheelabrator (small) did not lock out the machine prior to doing any servicing/maintenance of the equipment.    NOTE:  QUALITY CASTINGS COMPANY, WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD, OR ITS EQUIVALENT STANDARD 1910.147(d)(4)(i), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 314382557, CITATION NUMBER 1, ITEM NUMBER 5(b), AND WAS AFFIRMED AS A FINAL ORDER ON 10/22/10, WITH RESPECT TO A WORKPLACE AT 1200 N. MAIN STREET, ORRVILLE, OHIO
Recent events (4)
  • · F (S) $5775
  • · F (S) $5775
  • · C (S) $5775

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 331080994.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.