Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: STM CONSTRUCTION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of STM CONSTRUCTION, INC. in 839 PROSPECT, PARK RIDGE, IL 60068 (NAICS 238160). OSHA activity number 331081166.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch STM Construction, INC. — free Get an email when a new federal OSHA severe-injury report for STM Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
839 PROSPECT
City
PARK RIDGE
State
IL
ZIP
60068
Mailing
8643 W. FOSTER AVE #2B, CHICAGO, IL 60656
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
2
Ownership type
A

4 citations on file for this inspection.

1926.300 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 26, 2011
Abate by
Oct 27, 2011
Penalty
Initial $2,400 · Current $1,200 Reduced
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use:    a) A Makita portable saw was not equipped with a blade guard when provided for employee use to cut siding and trim materials.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2400

1926.451 E01

Serious Gravity 10 1 instance 1 exposed
Issued
Oct 26, 2011
Abate by
Oct 27, 2011
Penalty
Initial $4,200 · Current $2,100 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used:    a) Employees were not provided with safe access to scaffolding from which they were required to work at an elevation of approximately 16 feet.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $4200

1926.451 F03

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 26, 2011
Abate by
Oct 27, 2011
Penalty
Initial $3,000 · Current $1,500 Reduced
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity:    a) The employer did not have a competent person inspect scaffolding and scaffolding components before the work shift at the site.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1500
  • — Z (S) $3000

1926.451 G01 I

Serious Gravity 10 1 instance 1 exposed
Issued
Oct 26, 2011
Abate by
Oct 27, 2011
Penalty
Initial $4,200 · Current $2,100 Reduced
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system:    a) Employees were exposed to the hazard of falling approximately 16 feet while working from ladder jack scaffolding without the benefit of fall protection.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $4200

View STM Construction, INC.'s full OSHA safety record →