Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CADY CHEESE FACTORY, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of CADY CHEESE FACTORY, INC. in 126 HWY 128, WILSON, WI 54027 (NAICS 311513). OSHA activity number 331081315.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cady Cheese Factory, INC. — free Get an email when a new federal OSHA severe-injury report for Cady Cheese Factory, INC. is published. One employer, no account, unsubscribe in one click.
Site address
126 HWY 128
City
WILSON
State
WI
ZIP
54027
Mailing
126 HWY 128, WILSON, WI 54027
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311513
Employees
52
Ownership type
A

5 citations on file for this inspection.

1910.147 C07 I A

Serious Gravity 1 1 instance 7 exposed
Issued
Feb 13, 2012
Abate by
Mar 6, 2012
Penalty
Initial $2,100 · Current $1,260 Reduced
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolate:  (a) Cheese making area; Authorized employees cleaning equipment such as, cheese tables, were not trained in the recognition of hazardous energy sources, the type and magnitude of available energy, and the methods and means for energy isolation.
Recent events (2)
  • — I (S) $1260
  • — Z (S) $2100

1910.147 D04 I

Serious Gravity 1 1 instance 7 exposed
Issued
Feb 13, 2012
Abate by
Mar 6, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:  (a) Cheese making area; Each authorized employee cleaning cheese tables did not affix a lock to control hazardous sources of energy such as electrical, mechanical energy.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.333 B02 I

Serious Gravity 1 1 instance 1 exposed
Issued
Feb 13, 2012
Abate by
Mar 6, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.333(b)(2)(i): The employer did not maintain a written copy of the procedures outlined in paragraph (b)(2) of 29 CFR 1910.333 and did not make it available for inspection by the Assistant Secretary of Labor and his or her authorized representatives:  (a) Throughout the facility; Written electrical safe work procedures were not developed, maintained, or provided during this inspection.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 E02

Serious Gravity 1 1 instance 10 exposed
Issued
Feb 13, 2012
Abate by
Feb 21, 2012
Penalty
Initial $2,100 · Current $1,260 Reduced
29 CFR 1910.305(e)(2): Switches, circuit breakers and switchboards installed in wet locations were not enclosed in weatherproof enclosures:  (a) Packaging area, by tube washing station; A wall switch located in a wet area was not equipped with a weatherproof enclosure.
Recent events (2)
  • — I (S) $1260
  • — Z (S) $2100

1910.305 J02 VI

Repeat 1 instance 10 exposed
Issued
Feb 13, 2012
Abate by
Feb 21, 2012
Penalty
Initial $140 · Current $84 Reduced
29 CFR 1910.305(j)(2)(vi): A receptacle installed in a wet location where the product intended to be plugged into it was not to be attended while in use (for example, sprinkler system controllers, landscape lighting, and holiday lights) did not have an enclosure that was weatherproof with the attachment plug cap inserted or removed:  (a) Packaging area, by tube washing station; A receptacle located in a wet area was not provided with weatherproof enclosures.
Recent events (2)
  • — I (R) $84
  • — Z (R) $140

View Cady Cheese Factory, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331081315.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.