CINCINNATI, OH ·
OSHA Inspection: DIVERSAPACK, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DIVERSAPACK, LLC in 470 NORTHLAND BOULEVARD, CINCINNATI, OH 45240 (NAICS 323112). OSHA activity number 331082271.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DIVERSAPACK, LLC
- Site address
- 470 NORTHLAND BOULEVARD
- City
- CINCINNATI
- State
- OH
- ZIP
- 45240
- Mailing
- 470 NORTHLAND BOULEVARD, CINCINNATI, OH 45240
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323112
- Employees
- 74
- Ownership type
- A
Citations
12 citations on file for this inspection.
1910.106 A29
- Issued
- Nov 18, 2011
- Penalty
- Initial $4,250 · Current $2,200 Reduced
General-duty citation text
29 CFR 1910.106(a)(29): Approved safety can shall be used, that contain not more than 5 gallons capacity, having a spring-closing lid and spout cover and so designed that it will safely relieve internal pressure when subjected to fire exposure. a) The employer did not provide approved Class I flammable liquid dispensing container(s) to press operator(s) dispensing S-1615 Solvent Blend from a plastic milk jug.
Recent events (2)
- · I (S) $2200
- · Z (S) $4250
1910.106 E06 II
- Issued
- Nov 18, 2011
- Penalty
- Initial $4,250 · Current $2,200 Reduced
General-duty citation text
29 CFR 1910.106(e)(6)(ii): Class I liquids were dispensed into containers without the nozzle and container electrically interconnected: a) The S-1615 Solvent Blend Class I liquid material was not bonded during transfer from storage container to plastic dispense milk jug container by means of a bond wire.
Recent events (2)
- · I (S) $2200
- · Z (S) $4250
1910.147 D03
- Issued
- Nov 18, 2011
- Abate by
- Nov 21, 2011
- Penalty
- Initial $4,250 · Current $4,200 Reduced
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): a) Located in the Flexographic department where operator(s) changed out the roll plates on the Kitter press #5 and #6 printing machines and did not isolate the electrical power source at the electrical disconnect prior to making equipment service changes.
Recent events (2)
- · I (S) $4200
- · Z (S) $4250
1910.147 D04 I
- Issued
- Nov 18, 2011
- Abate by
- Nov 21, 2011
- Penalty
- Initial $4,250 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: a) Located in the Flexographic department where operator(s) changed out the roll plates on the Kitter printing machine did not affix a lock out or tag out device to the 240 AC volt electrical disconnect to Press #5 or #6 prior to making equipment service changes. b) Located in the Flexographic department where operator(s) washed down and cleaned roll plates on the Kitter printing machines did not affix a lock out or tag out device to the 240 AC volt electrical disconnect to Press #5 or #6 prior to that work. Operators relied on ineffective Inch Safe-Service mode procedures to perform that work and operators were exposed to in-going nip points at the roll plates.
Recent events (2)
- · I (S) $0
- · Z (S) $4250
1910.212 A01
- Issued
- Nov 18, 2011
- Penalty
- Initial $4,250 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by rotating saw blade: a) Located in the maintenance shop department twelve inches of the unused portion of the Do-All horizontal band saw blade was not guarded to protect operator from inadvertent contact.
Recent events (2)
- · I (S) $2100
- · Z (S) $4250
1910.332 B01
- Issued
- Nov 18, 2011
- Abate by
- Jan 30, 2012
- Penalty
- Initial $4,250 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments: a) The employer did not train their electricians in safetey related electrical work practices, including working near energized parts, and appropriate personal protective equipment, before employees performed troubleshooting and voltage testing on energized electrical equipment up to 480 AC volts.
Recent events (2)
- · I (S) $2100
- · Z (S) $4250
1910.332 B03
- Issued
- Nov 18, 2011
- Abate by
- Jan 30, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.332(b)(3): Qualified persons who are permitted to work on or near exposed energized parts were not trained in and familiar with the requirements of 1910.333(b)(3)(i) through 1910.333(b)(i)(iii): a) The maintenance personnel who conducted work on live energized parts during troubleshooting and voltage testing was not trained on the skills and techniques needed to determine the nominal voltage of the exposed parts, and the appropriate clearance distances for qualified persons.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.335 A01 II
- Issued
- Nov 18, 2011
- Abate by
- Nov 28, 2011
- Penalty
- Initial $4,250 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.335(a)(1)(ii): Protective equipment was not maintained in a safe, reliable condition and/or was not periodically inspected or tested: a) The 9-Kovak 1,000 AC Volt rated insulated rubber gloves used by employees in and around electrical 480 / 240 AC live voltage were not periodically inspected or tested as require by CFR 1910.137 to maintain safe level of protection.
Recent events (2)
- · I (S) $2100
- · Z (S) $4250
1910.137 B02 XII
- Issued
- Nov 18, 2011
- Abate by
- Nov 28, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.137(b)(2)(xii): The employer did not certify that electrical protective equipment had been tested in accordance with the requirements of paragraphs (b)(2)(viii), (b)(2)(ix), and (b)(2)(xi) of this section: a) The employer did not ensure that the 9-Kovak 1,000 AC volt rated rubber gloves electrical protective equipment were not periodically tested ever six month intervals.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.335 A01 V
- Issued
- Nov 18, 2011
- Abate by
- Dec 5, 2011
- Penalty
- Initial $4,250 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.335(a)(1)(v): Employees exposed to the danger of injury to the eyes or face from electric arcs or flashes or from flying objects resulting from electrical explosion did not wear protective equipment for the eyes and face. a) The employer did not ensure that maintenance employees were protected from electrical hazards when working on exposed energized parts up to 480 AC volt service while testing and changing out fuses. Employee(s) used a volt meter to troubleshoot live parts and were not provided with face and eye protection.
Recent events (2)
- · I (S) $2100
- · Z (S) $4250
1910.1200 F05 I
- Issued
- Nov 18, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein: a) The employer did not ensure that dispensing container that contained S-1615 Solvent Blend used to cleanse the roll plates in the press area were labeled to identify the content.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.1200 F05 II
- Issued
- Nov 18, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings: a) The employer did not ensure that dispensing container that contained S-1615 Solvent Blend used to cleanse the roll plates in the press area were labeled as to the health hazards of the chemical substance in the containers.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Diversapack, LLC
View Diversapack, LLC's full OSHA safety record →
More inspections in this industry (NAICS 323112)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331082271.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.