APPLETON, WI ·
OSHA Inspection: BRAGG HOME IMPROVEMENTS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of BRAGG HOME IMPROVEMENTS in 419 ROLLING MEADOWS, APPLETON, WI 54914 (NAICS 238160). OSHA activity number 331082461.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BRAGG HOME IMPROVEMENTS
- Site address
- 419 ROLLING MEADOWS
- City
- APPLETON
- State
- WI
- ZIP
- 54914
- Mailing
- 940 OAK STREET, WISCONSIN RAPIDS, WI 54494
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 6
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.501 B13
- Issued
- Feb 3, 2012
- Abate by
- Feb 6, 2012
- Penalty
- Initial $3,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph (b) Note: If using these systems was infeasible or created a greater hazard, the employer should develop and implement a fall protection plan meeting the requirements of paragraph (k) of 1926.502: a) On 09-20-11, employees who were on the upper level of a house roof were working on a 6:12 pitch with an eave edge greater than eighteen (18) feet above compacted surface without utilizing fall protection equipment. b) On 09-20-11, an employee who was working on the lower level of a house roof was working on a 6:12 pitch with an eave edge greater than eight and one half (8.5) feet above compacted surface. c) On 09-20-11, employees were walking/working on a 6:12 pitch garage roof with an eave edge greater than nine (9) feet above concrete surface without utilizing fall protection equipment. No Abatement Certification or Abatement Documentation required
Recent events (2)
- · I (S) $1000
- · Z (S) $3000
1926.503 B01
- Issued
- Feb 3, 2012
- Abate by
- Mar 19, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer: Employer was not able to provide a prepared certification for employee fall protection safety training for four (4) employees who did not recognize fall hazards when walking/working on roof surfaces which were greater than six (6) feet above compacted and/or concrete surfaces. Abatement Certification or Abatement Documentation required
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.1053 B04
- Issued
- Feb 3, 2012
- Abate by
- Feb 6, 2012
- Penalty
- Initial $3,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: On 09-20-11, employees were utilizing a folded, eight (8) foot, Werner step ladder as an access/egress from a lower roof surface to the second story roof surface of a home by leaning the top of the ladder against the upper eave edge. No Abatement Certification or Abatement Documentation required
Recent events (2)
- · I (S) $1000
- · Z (S) $3000
1926.1053 B09
- Issued
- Feb 3, 2012
- Abate by
- Feb 6, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(9): The area around the top and/or bottom of (a) ladder(s) was not kept clear: On 09-20-11, employees were stepping through debris at the base of an extension ladder which was used to access/egress a roof work surface. No Abatement Certification or Abatement Documentation required
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.1060 A01 III
- Issued
- Feb 3, 2012
- Abate by
- Mar 19, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1060(a)(1)(iii): The employer did not ensure that each employee using ladders and/or stairways had been trained by a competent person in the proper construction, use, placement, and care in handling the ladders and/or stairways: On 09-20-11, employees were not properly trained to recognized hazards associated with the use of a Werner eight (8) foot step ladder without opening the ladder as designed and without securing it when positioned on a surface that was not level. Abatement Certification or Abatement Documentation required
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections at Bragg Home Improvements
View Bragg Home Improvements's full OSHA safety record →