Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: M.V. PANGILINAN ENTERPRISES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of M.V. PANGILINAN ENTERPRISES, INC. in ALTERATION OF STRUCTURE FOR GUAM POLICE DEPT. BOAT PATROL OFFICES SOUTH MARINE CORPS DRIVE, HAGATNA, GU 96910 (NAICS 236220). OSHA activity number 331084327.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch M.V. Pangilinan Enterprises, INC. for free Get an email when a new federal OSHA severe-injury report for M.V. Pangilinan Enterprises, INC. is published. One employer, no account, unsubscribe in one click.
Site address
ALTERATION OF STRUCTURE FOR GUAM POLICE DEPT. BOAT PATROL OFFICES SOUTH MARINE CORPS DRIVE
City
HAGATNA
State
GU
ZIP
96910
Mailing
PO BOX D V, HAGATNA, GU 96932
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
8
Ownership type
Private (A)

4 citations on file for this inspection.

1926.404 B01 I

Serious Gravity 1 1 instance 2 exposed
Issued
Jan 5, 2012
Abate by
Jan 10, 2012
Penalty
Initial $1,785 · Current $1,200 Reduced
29 CFR 1926.404(b)(1)(i): The employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors:    (a) Near the east side of the building on or about November 2, 2011, there was no assured equipment grounding conductor program or ground-fault circuit-interrupter protection when an extension cord was used to power a 110 VAC, double insulated DeWalt sawsaw.  The sawsaw was used to cut 2x4s.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $1785

1926.404 F06

Serious Gravity 1 1 instance 2 exposed
Issued
Jan 5, 2012
Abate by
Jan 10, 2012
Penalty
Initial $1,785 · Current $1,200 Reduced
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, and enclosures was not permanent and continuous:    (a) Near the east side of the building on or about November 2, 2011, there was no grounding pin on the extension cord that was used to power a 110 VAC, double insulated DeWalt sawsaw.  The sawsaw was used to cut 2x4s.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $1785

1926.451 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 5, 2012
Abate by
Jan 10, 2012
Penalty
Initial $2,380 · Current $1,500 Reduced
29 CFR 1926.451(b)(1):  Each platform on all working levels of scaffolds were not fully planked or decked between the front uprights and the guardrail supports:    (a) Near the east side of the building on or about November 2, 2011, a mobile scaffold working level was not fully planked as there were 2, 16-inch wide planks between the uprights that were 58 inches apart. Employees on the scaffold removed sign boards from the building and repaired the glass on building.  The working level was 15 feet, 9 inches above the asphalt below.
Recent events (2)
  • · I (S) $1500
  • · Z (S) $2380

1926.452 W02

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 5, 2012
Abate by
Jan 10, 2012
Penalty
Initial $2,380 · Current $0 Reduced
29 CFR 1926.451(w)(2); Scaffold casters and wheels were not locked with positive wheel and/or wheel and swivel locks, or equivalent means, to prevent movement of the scaffold while the scaffold is used in a stationary manner:    (a) Near the east side of the building on or about November 2, 2011, one of the four wheels was not locked on a mobile scaffold. Employees on the scaffold removed sign boards from the building and repaired the glass on building.  The working level was 15 feet, 9 inches above the asphalt below.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2380

View M.V. Pangilinan Enterprises, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 331084327.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.