Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ARTEMIO GONZALEZ EXTERIORS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ARTEMIO GONZALEZ EXTERIORS in 6353 26TH AVE., KENOSHA, WI 53140 (NAICS 238160). OSHA activity number 331085001.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Artemio Gonzalez Exteriors — free Get an email when a new federal OSHA severe-injury report for Artemio Gonzalez Exteriors is published. One employer, no account, unsubscribe in one click.
Site address
6353 26TH AVE.
City
KENOSHA
State
WI
ZIP
53140
Mailing
3432 W. 60TH PLACE, CHICAGO, IL 60629
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
12
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Repeat Gravity 10 2 instances 3 exposed
Issued
Jan 19, 2012
Abate by
Jan 20, 2012
Penalty
Initial $9,240 · Current $9,240
29 CFR 1926.501(b)(13):     "Residential construction." Each employee engaged in residential construction activities 6 feet(1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provisionin paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it isinfeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets therequirements of paragraph (k) of 1926.502.Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fallprotection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complieswith 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.      (a)  Employees conducting roofing activities on a roof with a 10:12 pitch (main house) were not protected from falling to the lower level. This exposed employees to a fall hazard of approximately 21 feet.    (b)  Employees conducting roofing activities on a roof with a 6:12 pitch (garage) were not protected from falling to the lower level. This exposed employees to a fall hazard of approximately 8 feet.    Artemio Gonzalez Exteriors, was previously cited for a violation of this Occupational Safety and Health Standard or its equivalent 29 CFR 1926.501(b)(13), which was contained in OSHA Inspection #311401012, Citation 1, Item 1, which was affirmed as a final order on November 13th, 2008, with respect to the jobsite located at 1623/27 30th CT., Kenosha, WI 53140.
Recent events (4)
  • — R (R) $9240
  • — C (R) $9240
  • — F (R) $9240

1926.1053 B01

Repeat Gravity 5 2 instances 3 exposed
Issued
Jan 19, 2012
Abate by
Jan 20, 2012
Penalty
Initial $6,600 · Current $6,600
29 CFR 1926.1053(b)(1):     When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder.  In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.    (a)  The portable ladder being used for access to the roof (main house) did not extend at least 3 feet above the upper landing area.    (b)  The portable ladder being used for access to the roof (garage) did not extend at least 3 feet above the upper landing area.        Artemio Gonzalez Exteriors, was previously cited for a violation of this Occupational Safety and Health Standard or its equivalent 29 CFR 1926.1053 (b)(1), which was contained in OSHA Inspection #311401012, Citation 1, Item 2, which was affirmed as a final order on October 23rd, 2008, with respect to the jobsite located at 1623/27 30th CT., Kenosha, WI 53140.
Recent events (4)
  • — R (R) $6600
  • — C (R) $6600
  • — R (R) $6600

View Artemio Gonzalez Exteriors's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331085001.