Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: CALIFORNIA ARMY NATIONAL GUARD FMS #34

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CALIFORNIA ARMY NATIONAL GUARD FMS #34 in 1500 ARMORY DRIVE, SANTA ROSA, CA 95401 (NAICS 928110). OSHA activity number 331086397.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch California Army National Guard FMS #34 for free Get an email when a new federal OSHA severe-injury report for California Army National Guard FMS #34 is published. One employer, no account, unsubscribe in one click.
Site address
1500 ARMORY DRIVE
City
SANTA ROSA
State
CA
ZIP
95401
Mailing
1500 ARMORY DRIVE, SANTA ROSA, CA 95401
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
928110
Employees
9
Ownership type
Federal government (D)

5 citations on file for this inspection.

1910.305 A02 X

Serious Gravity 5 1 instance 9 exposed
Issued
Dec 2, 2011
Abate by
Dec 23, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.305(a)(2)(x):     Flexible cords and cables shall be protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points.    a)  East Bay 2 :  On August 1, 2011, and at times prior thereto, a flexible cord was laying across the aisle unprotected near the POL storage #6 & #7 and the Special Tool holding area creating a hazard.
Recent events (1)
  • · Z (S) $0

1910.157 B01

Serious Gravity 5 2 instances 9 exposed
Issued
Dec 2, 2011
Abate by
Dec 23, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.157(b)(1):     Where the employer has established and implemented a written fire safety policy which requires the immediate and total evacuation of employees from the workplace upon the sounding of a fire alarm signal and which includes an emergency action plan and a fire prevention plan which meet the requirements of 29 CFR 1910.38 and 29 CFR 1910.39 respectively, and when extinguishers are not available in the workplace, the employer is exempt from all requirements of this section unless a specific standard in part 1910 requires that a portable fire extinguisher be provided.      a)  Bays 1-4:  On or about August 1, 2011, and at times prior thereto, the Emergency  Fire Evacuation Maps posted did not show current changes in the evacuation routes and assembly areas for meeting points 1 & 2.
Recent events (1)
  • · Z (S) $0

1910.305 B01 II

Serious Gravity 5 1 instance 9 exposed
Issued
Dec 2, 2011
Abate by
Dec 23, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii):     Unused openings in cabinets, boxes, and fittings shall be effectively closed.    a)  West:  Mezzanine Level - Lunch Room:  On or about August 1, 2011, and at times prior thereto, there was a  4 square unmounted metal box with a loosened knock out on the underside located on top of a wooden cabinet.
Recent events (1)
  • · Z (S) $0

1910.305 G01 IV A

Serious Gravity 5 1 instance 9 exposed
Issued
Dec 2, 2011
Abate by
Dec 23, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A):     As a substitute for the fixed wiring of a structure;    East-Bay 2 :  On August 1, 2011, and at times prior thereto,  a  flexible cord was used  in place of  fixed wiring  from the outlet  above the flammable storage cabinet # 6 running across the floor through a hole in the rear of the desk.
Recent events (1)
  • · Z (S) $0

1910.303 E01

Serious Gravity 5 1 instance 9 exposed
Issued
Dec 2, 2011
Abate by
Dec 23, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.303(e)(1):     Identification of manufacturer and ratings. Electric equipment did not have markings giving voltage, current, wattage, or other ratings as necessary showing manufacturer's name or trademark.      Bay 2: On August 1, 2011, and at times prior thereto, a  flexible cord was used  in place of  fixed wiring  from the outlet  above the flammable storage cabinet # 6 running across the floor through a hole in the rear of the desk.  The flexible cord was plugged into a 4 square unmounted metal box placed on a metal trash can with plastic liner under the desktop creating an electrical and fire hazard .
Recent events (1)
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 331086397.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.