Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ADVANCE TANK AND CONSTRUCTION CO.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ADVANCE TANK AND CONSTRUCTION CO. in 500 LINDEN ST, FORT COLLINS, CO 80524 (NAICS 332420). OSHA activity number 331088120.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Advance Tank and Construction CO. — free Get an email when a new federal OSHA severe-injury report for Advance Tank and Construction CO. is published. One employer, no account, unsubscribe in one click.
Site address
500 LINDEN ST
City
FORT COLLINS
State
CO
ZIP
80524
Mailing
PO BOX 219, WELLINGTON, CO 80549
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332420
Employees
4
Ownership type
A

1 citation on file for this inspection.

1926.352 A

Other-than-serious 1 instance 3 exposed
Issued
Jan 13, 2012
Abate by
Feb 3, 2012
Penalty
Initial $4,590 · Current $4,590
29 CFR 1926.352(a):  Movable fire hazards in the vicinity of unmovable objects that were to be welded on, cut or heated were not taken to a safe place, or otherwise protected:    (a)  Advance Tank and Construction Co. at 500 Linden St, Fort Collins, CO 80524:  On November 7, 2011, the exposing employer did not ensure that combustible materials were protected or removed a safe distance from the cutting area during steel tank removal operations, in that a plasma torch was used to cut and remove a ladder that was attached to the side of steel tank #2 that measured approximately 40 feet in height, and 11 feet in diameter. A polyurethane insulation, a combustible material, coated the outside of the tank and was covered with metal cladding. On November 7, 2011, a fire occurred while using a plasma torch to cut and remove the ladder attachments from the tank. The cuts were made on the ladder attachments approximately 6 inches away from the side of the tank. Insulation was not removed from the multiple cut areas. This condition exposed employees to fire hazards.                                                  OR IN THE ALTERNATIVE    Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The employer did not furnish to each of his employees employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fire hazards while plasma cutting:    (a)  Advance Tank and Construction Co. at 500 Linden St, Fort Collins, CO 80524:  On November 7, 2011, the exposing employer did not ensure that combustible materials were protected or removed a safe distance from the cutting area during steel tank removal operations, in that a plasma torch was used to cut and remove a ladder that was attached to the side of steel tank #2 that measured approximately 40 feet in height, and 11 feet in diameter. A polyurethane insulation, a combustible material, coated the outside of the tank and was covered with metal cladding. On November 7, 2011, a fire occurred while using a plasma torch to cut and remove the ladder attachments from the tank. The cuts were made on the ladder attachments approximately 6 inches away from the side of the tank. Insulation was not removed from the multiple cut areas. This condition exposed employees to fire hazards.     A feasible method to prevent fire hazards during plasma cutting operations is to conduct the work in accordance with OSHA 29 CFR 1926.352 Fire Prevention, ANSI Z49.1-1967 Safety in Welding and Cutting, and NFPA No. 51B-1962 Cutting and Welding Processes. It is necessary to remove all fire hazards from the areas to be cut, in this case, the insulation surrounding the steel tank. The official fire report stated that the factors contributing to ignition was cutting/welding too close to a combustible. It also stated the factors affecting suppression effects was combustible insulation.    Another feasible method is to cut with a demolition saw that has the capability to safely cut through the steel. Combustible materials, i.e. the insulation, would still have to be removed a safe distance from the cutting area.
Recent events (2)
  • — I (O) $4590
  • — Z (S) $4590

View Advance Tank and Construction CO.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331088120.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.