Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ACTIVE ROOFING COMPANY, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ACTIVE ROOFING COMPANY, INC. in 699 N. WHEELING ROAD, MOUNT PROSPECT, IL 60056 (NAICS 238160). OSHA activity number 331088740.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Active Roofing Company, INC. — free Get an email when a new federal OSHA severe-injury report for Active Roofing Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
699 N. WHEELING ROAD
City
MOUNT PROSPECT
State
IL
ZIP
60056
Mailing
2100 W. 32ND ST., CHICAGO, IL 60608
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
8
Ownership type
A

2 citations on file for this inspection.

1926.501 B04 I

Other-than-serious 7 instances 8 exposed
Issued
Nov 29, 2011
Abate by
Nov 30, 2011
Penalty
Initial $4,900 · Current $4,900
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet above lower levels by personal fall arrest systems, covers, or guardrail systems erected around such holes:    a) Employees performing roofing work on a low-slope roof were exposed to a fall through unprotected skylights of approximately 21 feet.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (O) $4900
  • — Z (S) $4900

1926.252 A

Other-than-serious 1 instance 2 exposed
Issued
Nov 29, 2011
Penalty
Initial $0 · Current $0
29 CFR 1926.252(a): An enclosed chute of wood, or equivalent material, was not used where materials were dropped more than 20 feet to points lying outside the exterior walls of the building(s):    a) Waste roofing materials were dropped approximately 25 feet from the roof of the building into roll-off containers below without an enclosed chute.    No abatement certification or documentation required for this item.