MOUNT PROSPECT, IL —
OSHA Inspection: ACTIVE ROOFING COMPANY, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ACTIVE ROOFING COMPANY, INC. in 699 N. WHEELING ROAD, MOUNT PROSPECT, IL 60056 (NAICS 238160). OSHA activity number 331088740.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ACTIVE ROOFING COMPANY, INC.
- Site address
- 699 N. WHEELING ROAD
- City
- MOUNT PROSPECT
- State
- IL
- ZIP
- 60056
- Mailing
- 2100 W. 32ND ST., CHICAGO, IL 60608
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 8
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B04 I
- Issued
- Nov 29, 2011
- Abate by
- Nov 30, 2011
- Penalty
- Initial $4,900 · Current $4,900
General-duty citation text
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet above lower levels by personal fall arrest systems, covers, or guardrail systems erected around such holes: a) Employees performing roofing work on a low-slope roof were exposed to a fall through unprotected skylights of approximately 21 feet. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (O) $4900
- — Z (S) $4900
1926.252 A
- Issued
- Nov 29, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.252(a): An enclosed chute of wood, or equivalent material, was not used where materials were dropped more than 20 feet to points lying outside the exterior walls of the building(s): a) Waste roofing materials were dropped approximately 25 feet from the roof of the building into roll-off containers below without an enclosed chute. No abatement certification or documentation required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Active Roofing Company, INC.