OSHA Inspection: VA PUGET SOUND HEALTH CARE SYSTEM

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of VA PUGET SOUND HEALTH CARE SYSTEM in 9600 VETERANS DR. SW, TACOMA, WA 98493 (NAICS 622110). OSHA activity number 331088765.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch VA Puget Sound Health Care System — free Get an email when a new federal OSHA severe-injury report for VA Puget Sound Health Care System is published. One employer, no account, unsubscribe in one click.
Site address
9600 VETERANS DR. SW
City
TACOMA
State
WA
ZIP
98493
Mailing
1660 SOUTH COLUMBIA WAY, SEATTLE, WA 98108
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
622110
Employees
778
Ownership type
D

8 citations on file for this inspection.

1910.37 A03

Serious Gravity 1 1 instance 2 exposed
Issued
Nov 28, 2011
Abate by
Dec 16, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(3):  Exit route(s) were not kept free and unobstructed:    (a) Machine shop exit door was blocked by a welding machine.
Recent events (1)
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 1 1 exposed
Issued
Nov 28, 2011
Abate by
Dec 16, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii):  Unused openings in boxes, cabinets, or fittings were not effectively closed:    (a) Bldg 81 Lab breaker panel BCB 208/120 3phase was missing a breaker leaving a hole large enough for an employee to come in contact with live electrical parts.
Recent events (1)
  • — Z (S) $0

1910.157 C01

Other-than-serious 10 exposed
Issued
Nov 28, 2011
Abate by
Dec 16, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1):  Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:    (a) Bldg 132 Canteen, Kitchen area, Fire extinguisher was blocked by storage bins.
Recent events (1)
  • — Z (O) $0

1910.179 B05

Other-than-serious 2 exposed
Issued
Nov 28, 2011
Abate by
Jan 11, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.179(b)(5):  Rated load markings on crane(s) were not clearly legible from the ground or the floor:    (a) Machine/Welding Shop, No markings were visible from the ground that would indicate what the load capacity is.
Recent events (1)
  • — Z (O) $0

1910.303 B02

Other-than-serious 2 exposed
Issued
Nov 28, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2):  Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    (a) Carpenter Shop, Job made extension cord with metal box designed for wall installation.
Recent events (1)
  • — Z (O) $0

1910.303 F01

Other-than-serious 2 exposed
Issued
Nov 28, 2011
Abate by
Dec 16, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.303(f)(1):  Each service, feeder and branch circuit, at its disconnecting means or over current device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:    (a) Bldg 81 Lab, Breaker Panel 81BCLN3 had two 60amp breakers in the on  position  and no indication of there purpose.
Recent events (1)
  • — Z (O) $0

1910.303 G01

Other-than-serious 5 exposed
Issued
Nov 28, 2011
Abate by
Dec 16, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1):  Sufficient access and working space was not provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment:    (a) Bldg 81 Lab, Electrical panel BCB was blocked.
Recent events (1)
  • — Z (O) $0

1910.303 G02 I

Other-than-serious 1 exposed
Issued
Nov 28, 2011
Abate by
Dec 16, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(2)(i):  Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):    (a) Electrical storage room had a light with 2 florescent tubes less then 8 feet from the floor that were not guarded.
Recent events (1)
  • — Z (O) $0

View VA Puget Sound Health Care System's full OSHA safety record →