Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: GEN X METAL INDUSTRIES LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of GEN X METAL INDUSTRIES LLC in 1100 RANDOLPH STREET, VANDALIA, IL 62471 (NAICS 332999). OSHA activity number 331088989.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch GEN X Metal Industries LLC for free Get an email when a new federal OSHA severe-injury report for GEN X Metal Industries LLC is published. One employer, no account, unsubscribe in one click.
Site address
1100 RANDOLPH STREET
City
VANDALIA
State
IL
ZIP
62471
Mailing
14506 TIENDA DRIVE, CHESTERFIELD, MO 63017
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
7
Ownership type
Private (A)

2 citations on file for this inspection.

1910.178 Q01

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Dec 30, 2011
Abate by
Jan 3, 2012
Penalty
Initial $2,550 · Current $0 Reduced
29 CFR 1910.178(q)(1):     Any power-operated industrial truck not in safe operating condition was not taken out of service, and/or repairs were not made by authorized personnel:    Employees are exposed to forklift accidents due to faulty brakes on a Toyota Forklift, and the machine was not taken out of service.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2550

1910.303 G02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 30, 2011
Penalty
Initial $2,040 · Current $1,020 Reduced
29 CFR 1910.303(g)(2)(i):     Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):    Employees are exposed to electrical shock(s) while operating a baler device with a pendent box which was missing a cover exposing live parts.