VANDALIA, IL ·
OSHA Inspection: GEN X METAL INDUSTRIES LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of GEN X METAL INDUSTRIES LLC in 1100 RANDOLPH STREET, VANDALIA, IL 62471 (NAICS 332999). OSHA activity number 331088989.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GEN X METAL INDUSTRIES LLC
- Site address
- 1100 RANDOLPH STREET
- City
- VANDALIA
- State
- IL
- ZIP
- 62471
- Mailing
- 14506 TIENDA DRIVE, CHESTERFIELD, MO 63017
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 7
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.178 Q01
- Issued
- Dec 30, 2011
- Abate by
- Jan 3, 2012
- Penalty
- Initial $2,550 · Current $0 Reduced
General-duty citation text
29 CFR 1910.178(q)(1): Any power-operated industrial truck not in safe operating condition was not taken out of service, and/or repairs were not made by authorized personnel: Employees are exposed to forklift accidents due to faulty brakes on a Toyota Forklift, and the machine was not taken out of service.
Recent events (2)
- · I (S) $0
- · Z (S) $2550
1910.303 G02 I
- Issued
- Dec 30, 2011
- Penalty
- Initial $2,040 · Current $1,020 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): Employees are exposed to electrical shock(s) while operating a baler device with a pendent box which was missing a cover exposing live parts.
Recent events (2)
- · I (S) $1020
- · Z (S) $2040
More inspections in this industry (NAICS 332999)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 331088989.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.