GLENCOE, IL —
OSHA Inspection: ANCHOR MASONRY RESTORATION CONTRACTING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ANCHOR MASONRY RESTORATION CONTRACTING, INC. in 364 JACKSON AVE, GLENCOE, IL 60022 (NAICS 238140). OSHA activity number 331089367.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ANCHOR MASONRY RESTORATION CONTRACTING, INC.
- Site address
- 364 JACKSON AVE
- City
- GLENCOE
- State
- IL
- ZIP
- 60022
- Mailing
- 1509 FREEMONT DRIVE, HANOVER PARK, IL 60133
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 4
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.451 B01
- Issued
- Dec 6, 2011
- Abate by
- Dec 7, 2011
- Penalty
- Initial $4,200 · Current $2,100 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels was not fully planked or decked between front uprights and the guardrail supports: a) Employees were exposed to fall hazards of greater than 25 while working on the scaffold platform which was not fully decked. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $2100
- — Z (S) $4200
1926.451 G01
- Issued
- Dec 6, 2011
- Abate by
- Dec 7, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to that lower level: a) Employees working from frame scaffolding were exposed to fall hazards of greater than 25 feet. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.