GREENDALE, WI ·
OSHA Inspection: THE KINETIC CO., INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of THE KINETIC CO., INC. in 6775 LOOMIS ROAD, GREENDALE, WI 53129 (NAICS 333515). OSHA activity number 331089847.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- THE KINETIC CO., INC.
- Site address
- 6775 LOOMIS ROAD
- City
- GREENDALE
- State
- WI
- ZIP
- 53129
- Mailing
- P O BOX 200, GREENDALE, WI 53129
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333515
- Employees
- 87
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Jan 26, 2012
- Abate by
- Feb 16, 2012
- Penalty
- Initial $3,850 · Current $2,300 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: (a) In the Heat Treat area; a lifting collar was used to move fixtures. The lifting collar did not have the rated load or any identification exposing employees to struck by hazards.
Recent events (2)
- · I (S) $2300
- · Z (S) $3850
1910.147 C06 II
- Issued
- Jan 26, 2012
- Abate by
- Jan 27, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The periodic inspection certification of energy control procedures did not contain the required documentation on identification of the machine or equipment, inspection date, employees included, and the person performing the ins (a) The employer did not have all of the elements of a certified periodic inspection.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at The Kinetic CO., INC.
View The Kinetic CO., INC.'s full OSHA safety record →
More inspections in this industry (NAICS 333515)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 331089847.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.