NAMPA, ID ·
OSHA Inspection: SELKIRK CORPORATION
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of SELKIRK CORPORATION in 1820 E. FARGO AVENUE, NAMPA, ID 83687 (NAICS 332322). OSHA activity number 331090100.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SELKIRK CORPORATION
- Site address
- 1820 E. FARGO AVENUE
- City
- NAMPA
- State
- ID
- ZIP
- 83687
- Mailing
- 1820 E. FARGO AVENUE, NAMPA, ID 83687
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332322
- Employees
- 150
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.37 B04
- Issued
- Dec 12, 2011
- Abate by
- Jan 4, 2012
- Penalty
- Initial $2,550 · Current $1,275 Reduced
General-duty citation text
29 CFR 1910.37(b)(4): Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent: a) Main manufacturing plant: On November 15, 2011, and times prior thereto, there were no signs posted in the plant indicating the direction to the nearest exit when the direction of travel to the exit was not immediately apparent. Note: Abatement certification is required for this item.
Recent events (2)
- · I (O) $1275
- · Z (S) $2550
1910.145 C02 I
- Issued
- Dec 12, 2011
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.145(c)(2)(i): Caution signs were not used to warn against potential hazards or to caution against unsafe practices: Main manufacturing plant: On November 15, 2011, and times prior thereto, employees were operating a Carando vent pipe seamer that did not have caution signs or floor markings to define the safe operating zone when it opens back up toward the operator after it completes the production cycle. Note: Abatement certification is not required for this item
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.147 C06 I
- Issued
- Dec 12, 2011
- Abate by
- Jan 4, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic review of the energy control procedures as least annually to ensure that the procedures and the requirements of the standards are met: a) Main manufacturing plant: On November 15, 2011, and times prior thereto, employees were perfoming maintenance and service on the Corando Model 531-1 vent pipe production machine and were using LOTO procedures that had not been reviewed at least annually. Note: Abatement certification is required for this item.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Selkirk Corporation