WILLISTON, ND ·
OSHA Inspection: VASQUEZ, WALTER A DBA 3 CONSTRUCTION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of VASQUEZ, WALTER A DBA 3 CONSTRUCTION in 926 SPRING CREEK DRIVE, WILLISTON, ND 58801 (NAICS 238130). OSHA activity number 331091397.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VASQUEZ, WALTER A DBA 3 CONSTRUCTION
- Site address
- 926 SPRING CREEK DRIVE
- City
- WILLISTON
- State
- ND
- ZIP
- 58801
- Mailing
- 3175 WEST FLOYD AVENUE APT D-201, ENGLEWOOD, CO 80110
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 5
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1910.178 L01 I
- Issued
- Jan 31, 2012
- Abate by
- Feb 17, 2012
- Penalty
- Initial $1,530 · Current $765 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): (a) Vasquez, Walter A dba 3 Construction at 926 Spring Creek Drive, Williston, ND 58801: On or before October 28, 2011, the employer did not ensure that employees were trained and evaluated to operate the Terex TH844C rough terrain forklift. Condition exposed employees to struck-by hazards. Abatement Note: 1926.602(d), powered industrial truck operator training, provides that the requirements applicable to construction work under this paragraph are identical to those set forth in 1910.178(l) of this chapter.
Recent events (2)
- · I (S) $765
- · Z (S) $1530
1926.501 B13
- Issued
- Jan 31, 2012
- Penalty
- Initial $1,301 · Current $650 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems: (a) Vasquez, Walter A dba 3 Construction at 926 Spring Creek Drive, Williston, ND 58801: On or before October 28, 2011, the employer did not ensure that employees were using fall protection when framing this house in the following instances: 1. An open stairway hole measuring 12' x 42" was not guarded or covered, with a 9'4" fall hazard to the basement; 2. Two open elevator holes, each measuring about 8' x 41", were not guarded or covered, each with a 9'4" fall hazard to the basement; 3. Four window well holes, each measuring 45" x 64", were not covered, each with a 6'3" fall hazard to the basement; and 4. One elevated plank was not secured to prevent it from sliding off its support bracket, with a fall hazard of 9'2". Conditions exposed employees to fall hazards of up to 9'4".
Recent events (2)
- · I (S) $650
- · Z (S) $1300.5
1926.403 B02
- Issued
- Jan 31, 2012
- Abate by
- Feb 17, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: (a) Vasquez, Walter A dba 3 Construction at 926 Spring Creek Drive, Williston, ND 58801: On or before October 28, 2011, the employer was using a metal 4-plex electrical outlet box on the ground of the interior of the house to power 110-volt hand tools, and this metal outlet box was not certified for such use. A ground-fault circuit interrupter was in use. Condition exposed employees to electrical shock hazards.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1926.404 F06
- Issued
- Jan 31, 2012
- Abate by
- Feb 17, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(f)(6): The path-to-ground from circuits, equipment, or enclosures was not permanent and continuous: (a) Vasquez, Walter A dba 3 Construction at 926 Spring Creek Drive, Williston, ND 58801: On or before October 28, 2011, the employer was using a yellow extension cord with an open ground to power a 110-volt Skilsaw, model HD77M, serial number 988 34623. The saw was not double insulated, but was used with a ground-fault circuit interrupter, in the interior of the house. Condition exposed employees to electrical shock hazards.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 238130)
More inspections in ND
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 331091397.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.