FRANKLIN, OH ·
OSHA Inspection: NATION COATING SYSTEMS, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of NATION COATING SYSTEMS, INC. in 501 SHOTWELL DRIVE, FRANKLIN, OH 45005 (NAICS 332812). OSHA activity number 331091629.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NATION COATING SYSTEMS, INC.
- Site address
- 501 SHOTWELL DRIVE
- City
- FRANKLIN
- State
- OH
- ZIP
- 45005
- Mailing
- 501 SHOTWELL DRIVE, FRANKLIN, OH 45005
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332812
- Employees
- 12
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.253 B02 II
- Issued
- Dec 2, 2011
- Abate by
- Dec 5, 2011
- Penalty
- Initial $2,040 · Current $1,428 Reduced
General-duty citation text
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces shall be located where cylinders will not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons. a. At the dock area in which full acetylene, oxygen, nitrogren, hydrogen and propane cylinders were being stored, there was a potential for damage from forklift and/or falling objects being transported during loading or unloading of trucks.
Recent events (2)
- · I (S) $1428
- · Z (S) $2040
1910.253 B04 III
- Issued
- Dec 2, 2011
- Abate by
- Dec 5, 2011
- Penalty
- Initial $2,040 · Current $1,428 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour. a. At the dock area, there were helium, oxygen, and argon cylinders in storage that were 5 feet 4 inches away from fuel gas cylinders, i.e., acetylene and propane.