Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: CIRQUE RESOURCES L.P

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CIRQUE RESOURCES L.P in S-16 T-142N R-90W, GOLDEN VALLEY, ND 58541 (NAICS 213111). OSHA activity number 331091884.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cirque Resources L.P for free Get an email when a new federal OSHA severe-injury report for Cirque Resources L.P is published. One employer, no account, unsubscribe in one click.
Site address
S-16 T-142N R-90W
City
GOLDEN VALLEY
State
ND
ZIP
58541
Mailing
475 17TH ST. SUITE 160D, DENVER, CO 80202
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213111
Employees
19
Ownership type
A

8 citations on file for this inspection.

1910.23 A08 II

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 26, 2012
Abate by
Mar 29, 2012
Penalty
Initial $2,550 · Current $1,275 Reduced
29 CFR 1910.23(a)(8)(ii):  A floor hole into which persons can accidentally walk into was not guarded by a floor hole cover of standard strength and construction:    a) On or about October 30, 2011 and times prior, Cirque Resources LP, as controlling/exposing employer, did not ensure that DHS Drilling Company, Inc, a subcontractor, protected their employees from injury in that, half of the cellar floor cover was missing. The opening was 4 foot by 2 foot.
Recent events (2)
  • · I (S) $1275
  • · Z (S) $2550

1910.24 B

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 26, 2012
Abate by
Mar 29, 2012
Penalty
Initial $1,530 · Current $765 Reduced
29 CFR 1910.24(b): Fixed stairs was not provided for access from one structure level to another where operations necessitated travel regularly, daily, or at each shift:    a) On or about October 30, 2011, and at times prior, Cirque Resources LP, as controlling/exposing employer, did not ensure that DHS Drilling Company, Inc., a subcontractor, protected their employees from injury while accessing the outside restroom in that, employees were exposed to falling/tripping and slipping hazards where a 24 inch break in elevation existed.
Recent events (2)
  • · I (S) $765
  • · Z (S) $1530

1910.24 H

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 26, 2012
Abate by
Mar 29, 2012
Penalty
Initial $2,550 · Current $0 Reduced
29 CFR 1910.24(h):  Standard railing(s) was not provided on the open side(s) of all fixed industrial stairway(s) and stair platform(s):    a) On or about October 30, 2011, and times prior, Cirque Resources LP, as controlling/exposing employer, did not ensure that DHS Drilling Company, Inc., a subcontractor, protected their employees from falls approximately 78 inches while using the fixed stairs to accessing the Mud Tanks in that the handrail was missing.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2550

1910.142 D10

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 26, 2012
Abate by
Mar 27, 2012
Penalty
Initial $1,530 · Current $765 Reduced
29 CFR 1910.142(d)(10): Privies and toilet rooms was not kept in a sanitary condition. They were not cleaned at least daily:    a) On or about October 30, 2011, and at times prior, Cirque Resources LP, as controlling/exposing employer, did not ensure that DHS Drilling Company, Inc., a subcontractor, protected their employees from illness in that, the outside restroom for employees was not cleaned daily and more often if needed.
Recent events (2)
  • · I (S) $765
  • · Z (S) $1530

1910.151 C

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 26, 2012
Abate by
Mar 29, 2012
Penalty
Initial $2,550 · Current $1,275 Reduced
29 CFR 1910.151(c): Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body was not provided within the work area for immediate emergency use:    a) On or about October 30, 2011, and at times prior, Cirque Resources LP, as controlling/exposing employer, did not ensure that DHS Drilling Company, Inc. a subcontractor, protected their employees from injury in that, the eye wash station located at the mixing area did not have any flushing fluid in it.
Recent events (2)
  • · I (S) $1275
  • · Z (S) $2550

1910.157 E02

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 26, 2012
Abate by
Mar 27, 2012
Penalty
Initial $1,530 · Current $765 Reduced
29 CFR 1910.157(e)(2): Portable fire extinguishers or hose used in lieu thereof under paragraph (d)(3) of this section was not visually inspected monthly:    a) On or about October 30, 2011, and at times prior, Cirque Resources LP, as controlling/exposing employer, did not ensure that DHS Drilling Company, Inc., a subcontractor, protected their employees from injury in that, several fire extinguishers (11) had not been visually inspected monthly or tagged out of service.
Recent events (2)
  • · I (S) $765
  • · Z (S) $1530

1910.219 C02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 26, 2012
Abate by
Mar 29, 2012
Penalty
Initial $2,550 · Current $1,275 Reduced
29 CFR 1910.219(c)(2)(i): All exposed parts of horizontal shafting seven (7) feet or less from floor or working platform, excepting runways used exclusively for oiling, or running adjustments, was not protected by a stationary casing enclosing shafting completely or by a trough enclosing sides and top or sides and bottom of shafting as location requires:    a) On or about October 30, 2011, and at times prior, Cirque Resources LP, as controlling/exposing employer, did not ensure that DHS Drilling Company, Inc., a subcontractor, protected their employees from injury in that, the Pony Rod at the Pump House was not guards were not in place.    b) On or about October 30, 2011, and at times prior, Cirque Resources LP, as controlling/exposing employer, did not ensure that DHS Drilling Company, Inc., a subcontractor, protected their employees from injury in that, the Charge Pump was not guarded.
Recent events (2)
  • · I (S) $1275
  • · Z (S) $2550

1910.305 A02 X

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 26, 2012
Abate by
Mar 27, 2012
Penalty
Initial $2,040 · Current $1,020 Reduced
29 CFR 1910.305(a)(2)(x): Flexible cords and cables was not protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points:    a) On or about October 30, 2011, and at times prior, Cirque Resources LP, as controlling/exposing employer, did not ensure that DHS Drilling Company, Inc., a subcontractor, protected their employees from injury in that, the flexible cord used to power the heater in the outside restroom had been run over and had not been installed in accordance with the manufactures recommendation.
Recent events (2)
  • · I (S) $1020
  • · Z (S) $2040

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331091884.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.