ARVADA, CO —
OSHA Inspection: EURO CABINET CORPORATION
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of EURO CABINET CORPORATION in 6110 WEST 55TH AVENUE, ARVADA, CO 80002 (NAICS 337110). OSHA activity number 331092676.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EURO CABINET CORPORATION
- Site address
- 6110 WEST 55TH AVENUE
- City
- ARVADA
- State
- CO
- ZIP
- 80002
- Mailing
- 6110 WEST 55TH AVENUE, ARVADA, CO 80002
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337110
- Employees
- 13
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.147 C04 I
- Issued
- Jan 26, 2012
- Abate by
- Apr 9, 2012
- Penalty
- Initial $2,025 · Current $1,620 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in the activities covered by this section: a) On or about November 10, 2011, and at times prior, employees were exposed to caught-in hazards and amputations because the employer did not develop adequate energy control procedures and ensure that they were understood and used by employees. Energy isolating devices were not utilized by all employees who performed hazardous tasks such as changing blades on the large table saws.
Recent events (2)
- — I (O) $1620
- — Z (S) $2025
1910.147 D04 I
- Issued
- Jan 26, 2012
- Abate by
- Jan 27, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: a) On or about November 10, 2011, and at times prior, employees were exposed to caught-in hazards and amputations because they did not affix locks to energy isolating devices while they performed hazardous tasks such as changing blades on the large table saws.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.213 H01
- Issued
- Jan 26, 2012
- Abate by
- Apr 9, 2012
- Penalty
- Initial $2,025 · Current $1,620 Reduced
General-duty citation text
29 CFR 1910.213(h)(1): The sides of the lower exposed portion of the blade were not guarded to the full diameter of the blade by a device that will automatically adjust itself to the thickness of the stock and remained in contact with stock being cut to give maximum protection possible for the operation being performed: a) On or about November 10, 2011, and at times prior, employees were exposed to lacerations and amputations while they operated the Ezy-Mitre radial saw (panel saw) in the shop area because the saw did not have a guard which covered the lower half of the blade.
Recent events (2)
- — I (O) $1620
- — Z (S) $2025
1910.213 I01
- Issued
- Jan 26, 2012
- Abate by
- Apr 9, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(i)(1): All portions of the saw blade were not enclosed or guarded, except for the working portion of the blade between the bottom of the guide rolls and the table. The guard for the portion of the blade between the sliding guide and the upper-saw-wheel guard did not protect the saw blade at the front and outer side: a) On or about November 10, 2011, and at times prior, employees were exposed to lacerations and amputations while working with a bandsaw that was not adequately guarded above the guide rolls.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.132 D02
- Issued
- Jan 26, 2012
- Abate by
- Apr 9, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed: a) On or about November 10, 2011, and at times prior, the employer did not verify, through written certification, that a hazard assessment of the workplace had been performed to determine the type of personal protective equipment necessary to protect employees from such hazards as chemicals, flying chips and particles, and power tools.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.138 A
- Issued
- Jan 26, 2012
- Abate by
- Mar 9, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.138(a): The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasions; punctures; chemical burns; thermal burns; and harmful temperature extremes: a) On or about November 10, 2011, and at times prior, employees were exposed to absorption of chemicals through the skin while they used products such as Formica 200 Adhesive Spray, which contained 45-55% methylene chloride, without the use of gloves.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.22 D01
- Issued
- Jan 26, 2012
- Abate by
- Mar 9, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed to the building: a) On or about November 10, 2011, and at times prior, employees were exposed to struck-by or crushed-by hazards while they worked near or under the ceiling to the office and break areas because materials were stored above the ceiling and the employer had not posted the load rating for the ceiling/floor structure.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1052 D02
- Issued
- Jan 26, 2012
- Abate by
- Mar 9, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1052(d)(2): The employer did not perform initial monitoring to determine each employee's exposure to methylene chloride: a) On or about November 10, 2011, and at times prior, employees were exposed to unknown concentrations of methylene chloride because the employer failed to conduct an initial exposure assessment for employees that used F-200 Adhesive Spray, which contained 45-55% methylene chloride, to adhere laminate strips to cabinetry pieces.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 F05 I
- Issued
- Jan 26, 2012
- Abate by
- Mar 9, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein: a) On or about November 10, 2011, and at times prior, several containers of cleaners and other chemicals were not labeled with the identity of the hazardous chemicals contained within. Without such information, employees were exposed to potential overexposure to the chemicals and/or hazardous reactions between incompatible chemicals.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Euro Cabinet Corporation
View Euro Cabinet Corporation's full OSHA safety record →
More inspections in this industry (NAICS 337110)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331092676.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.