Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,249Inspections Most recent open 2026-08-20 Last loaded 2026-08-24

OSHA Inspection: GENERAL ELECTRIC COMPANY

Other inspection · Safety discipline

On , OSHA opened an other safety inspection of GENERAL ELECTRIC COMPANY in ONE NEUMAN WAY, CINCINNATI, OH 45215 (NAICS 336412). OSHA activity number 331093088.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch General Electric Company for free Get an email when a new federal OSHA severe-injury report for General Electric Company is published. One employer, no account, unsubscribe in one click.
Site address
ONE NEUMAN WAY
City
CINCINNATI
State
OH
ZIP
45215
Mailing
ONE NEUMANN WAY, CINCINNATI, OH 45215
Inspection type
Other (L)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336412
Employees
2000
Ownership type
Private (A)

2 citations on file for this inspection.

1910.38 C03

Other-than-serious 1 instance 6 exposed
Issued
Feb 14, 2012
Abate by
Mar 28, 2012
Penalty
Initial $5,000 · Current $5,000
29 CFR 1910.38(c)(3):   Minimum elements of an emergency action plan. An emergency action plan must include at a minimum:   Procedures to be followed by employees who remain to operate critical plant operations before they evacuate;      On or about November 21, 2011 an explosion and fire occurred in Building 401A and the evacuation plan was not adequate in that:    a) As required by 1910.120 (q)(1), procedures had not been developed for Turbo Air Operators located in Building 401 control room to follow when required to remain in the control room until the Test Cells were shut down before operators could evacuate;    b) Emergency shutdown procedures had not been updated for equipment such as but not limited to compressors,  pignones and boosters located in Bldg 401 and 401A after the installation of computers in the control room.
Recent events (2)
  • · I (O) $5000
  • · Z (S) $5000

1910.38 F02

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 14, 2012
Abate by
Mar 28, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.38(f)(2):     Review of emergency action plan. An employer must review the emergency action plan with each employee covered by the plan when the employee's responsibilities under the plan change;     The employer did not ensure that the plan was reviewed with Turbo Air operators in Building 401 when the plan changed from employees evacuating to employees shutting down operations and performing emergency response prior to evacuation in that on or about November 21, 2011 employees remained in the control room until the test cell was shut down even though an evacuation order by the fire department had been initiated.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

View General Electric Company's full OSHA safety record →