Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: QUAM-NICHOLS COMPANY

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of QUAM-NICHOLS COMPANY in 234 E. MARQUETTE RD., CHICAGO, IL 60637 (NAICS 334310). OSHA activity number 331094086.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Quam-Nichols Company — free Get an email when a new federal OSHA severe-injury report for Quam-Nichols Company is published. One employer, no account, unsubscribe in one click.
Site address
234 E. MARQUETTE RD.
City
CHICAGO
State
IL
ZIP
60637
Mailing
234 E. MARQUETTE RD., CHICAGO, IL 60637
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
334310
Employees
67
Ownership type
A

11 citations on file for this inspection.

1910.134 C01

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 30, 2012
Abate by
Jun 12, 2012
Penalty
Initial $2,100 · Current $1,050 Reduced
29 CFR 1910.134(c)(1):  The employer did not ensure that a written respiratory protection program with worksite-specific procedures was established and implemented to include the provisions of (i)-(ix), as applicable:    a.  On or about November 23, 2011,  in the facility,  the employees were provided with and required to wear half mask air purifying respirators for use during manual electrostatic powder coating operations.  The employer did not develop or implement a written respirator program that included the provisions in 1910.134(c)(1)(i)-(ix) with worksite specific procedures was not established and implemented for required use.
Recent events (2)
  • — I (S) $1050
  • — Z (S) $2100

1910.134 E01

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 30, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:    a.  On or about November 23, 2011,  in the facility,  the employees were provided with and required to wear half mask air purifying respirators for use during manual electrostatic powder coating operations.  Employees required to wear tight fitting respirators had not received a medical evaluation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 F02

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 30, 2012
Abate by
May 21, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(2):  Employee(s) using a tight-fitting facepiece respirator were not annually fit tested:    a. On or about November 23, 2011, in the facility,  employee(s) were required to wear Pro Tech half-mask respirators with cartridges during manual electrostatic powder coating operations.  Employees required to wear tight-fitting respirators had not been fit tested.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 H03

Serious Gravity 1 2 instances 1 exposed
Issued
Apr 30, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.134(h)(3)(ii)[A]: The employer did not ensure that respirator inspections included a check of respirator function,  tightness of connections,  and the condition of the various parts including,  but not limited to, the facepiece,  head straps,  valves,  connecting tube,  and cartridges, canisters or filters:      a.  On or about November 23, 2011,  in the facility,  the employees were provided with and required to wear half mask air purifying respirators for use during manual electrostatic powder coating operations.  The employer did not ensure that respirator inspections included a check of the valves of  two (2) Pro-Tech half mask tight fitting respirators worn by powder coating employees.  The valves were missing from the respirator.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 K

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 30, 2012
Abate by
Jun 12, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k): The employer did not provide comprehensive, understandable training which did not occur annually and/or more often if necessary:    a. On or about November 23, 2011, in the facility, in the facility,  employee(s) were required to wear Pro Tech half-mask respirators with cartridges during manual electrostatic powder coating operations.  Employees required to wear tight-fitting respirators had not received respirator training.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.136 A

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 30, 2012
Abate by
May 21, 2012
Penalty
Initial $2,100 · Current $1,050 Reduced
29 CFR 1910.136(a): The employer did not ensure that each affected employee uses protective footwear when working in areas where there is a danger of foot injuries due to falling or rolling objects, or objects piercing the sole, and where such employee's feet are exposed to electrical hazards:    a.  On or about December 6, 2011,  in the punch press area,  employees were required to lift steel coils weighing approximately 3000 pounds.  The employer did not require employees to wear adequate metatarsal foot protection to protect employees from foot injury hazards.
Recent events (2)
  • — I (S) $1050
  • — Z (S) $2100

1910.151 C

Serious Gravity 1 1 instance 11 exposed
Issued
Apr 30, 2012
Penalty
Initial $2,100 · Current $1,050 Reduced
29 CFR 1910.151(c):     Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:    a. On or about November 23, 2011,  in the white powder coating department,  employees regularly worked with corrosive chemicals such as KCI Liqua Phos 6929 (phosphoric acid & nitric acid).  Yet,  an eyewash was not provided in the white powder area for quick drenching or flushing of the eyes.
Recent events (2)
  • — I (S) $1050
  • — Z (S) $2100

1910.184 I09 III

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 30, 2012
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.184(i)(9)(iii): Synthetic web sling(s) with snags, punctures, tears, or cuts were not immediately removed from service:    a.  On or about December 6, 2011,  in the punch press area,  a synthetic nylon sling with rips and tears were used by employee(s) to lift a steel coil weighing approximately 3000 pounds.  The employees were thereby exposed to the hazards associated with being struck by a steel coil.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.305 J01 I

Serious Gravity 5 1 instance 5 exposed
Issued
Apr 30, 2012
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.305(j)(1)(i): Fixtures, lampholders, lamps, rosettes, and receptacles located had live parts normally exposed to employee contact:    a. On or about December 6, 2011,  in the punch press area, the electrical box on the back of a halogen lamp was broken and pulled away exposing internal wiring, thereby exposing live electrical parts.  The employees were thereby exposed to the hazards associated with live electrical parts.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.1200 H01

Serious Gravity 1 1 instance 67 exposed
Issued
Apr 30, 2012
Abate by
Jun 12, 2012
Penalty
Initial $2,100 · Current $1,050 Reduced
29 CFR 1910.1200(h)(1):     Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:    a. On or about November 23, 2011,  in the facility, employees required to manufacture loadspeakers and loudspeaker assemblies were exposed to contact with hazardous materials,  including but not limited to powder coatings (epichlorohydrin, epoxy resin, titanium dioxide), nitric acid,  phosphoric acid, nitrogen, oxygen, press lubricants & associated manufacturing chemicals. Employees were not provided with effective information & training on hazardous chemicals.
Recent events (2)
  • — I (S) $1050
  • — Z (S) $2100

1910.101 B

Other-than-serious 1 instance 15 exposed
Issued
Apr 30, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6.  Compressed gas cylinder(s) in use were not properly supported to prevent them from being knocked over:    a.  On or about December 6, 2011,  in the white powder coating area,  a nitrogen cylinder was not secured to avoid the possibility of being knocked over.