Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: G2 REVOLUTION LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of G2 REVOLUTION LLC in 200 STANFORD PARKWAY, FINDLAY, OH 45840 (NAICS 562920). OSHA activity number 331095018.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch G2 Revolution LLC — free Get an email when a new federal OSHA severe-injury report for G2 Revolution LLC is published. One employer, no account, unsubscribe in one click.
Establishment
G2 REVOLUTION LLC
Site address
200 STANFORD PARKWAY
City
FINDLAY
State
OH
ZIP
45840
Mailing
14601 CR 212, FINDLAY, OH 45840
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
562920
Employees
17
Ownership type
A

4 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 15 exposed
Issued
May 9, 2012
Abate by
Jun 11, 2012
Penalty
Initial $4,200 · Current $2,310 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fire hazards created by an oil burning heater which was modified by the company to accept a fuel source which was not approved by the manufacturer.    a. G2 Revolution, LLC located at 200 Stanford Parkway in Findlay, Ohio:  On or about November 18, 2011, the employer did not ensure that the oil fired heater located on the south side of the facility was burning fuel approved by the manufacturer.  The employer was burning an alcohol based hand sanitizer with a flash point of 77 degrees fahrenheit rather than a manufacturer approved fuel with a flash point of at least 140 degrees fahrenheit.  The alcohol based hand sanitizer caught fire inside of the heater and then dripped out of the furnace housing and ignited a plastic 275 gallon tote of alcohol based hand sanitizer sitting under the heater.  The fire spread to adjacent combustible materials stored around the heater and subsequently caught the entire facility on fire.     Abatement Note:  Among other methods, one feasible and acceptable abatement method to correct this hazard is to comply with the manufactures Installation and Operation Manual (October 2011) Waste-Oil Furnace Models: EL-200H, but not limited to: a) Ensure fuels used by the heating system have flash points between 140 degrees F and 400 degrees F. b) Ensure the heater is being installed and operated according to the Installation and Operation Manual.
Recent events (2)
  • — I (S) $2310
  • — Z (S) $4200

1910.1200 H03 II

Serious Gravity 10 1 instance 2 exposed
Issued
May 9, 2012
Abate by
May 16, 2012
Penalty
Initial $4,200 · Current $2,310 Reduced
29 CFR 1910.1200(h)(3)(ii): The employer did not provide employees with effective information and training on the physical and health hazards of the chemicals in the work area:    a. G2 Revolution, LLC located at 200 Stanford Parkway in Findlay, Ohio:  On or about November 18, 2011, the employer did not ensure that employees required to perform tasks such as crushing perfume bottles and handling hand sanitizer  were trained on the physical and health hazards of ethanol.
Recent events (2)
  • — I (S) $2310
  • — Z (S) $4200

1910.106 E02 II B 2

Serious Gravity 10 1 instance 20 exposed
Issued
May 9, 2012
Penalty
Initial $4,200 · Current $2,310 Reduced
29 CFR 1910.106(e)(2)(ii)(b)(2): The quantity of liquid that may be located outside of an inside storage room or storage cabinet in a building or in any one fire area of a building shall not exceed 120 gallons of Class IB, IC, II, or III liquids in containers:    a. G2 Revolution, LLC located at 200 Stanford Parkway in Findlay, Ohio:  On or about November 18, 2011, the employer did not ensure that the quantity of flammable liquids such as Purell hand sanitizer located at the north end of the facility did not exceed 120 gallons.  There was approximately 3,000 gallons of hand sanitizer on pallets located in one area near the north end of the facility.
Recent events (2)
  • — I (S) $2310
  • — Z (S) $4200

1910.106 E05 I

Serious Gravity 10 1 instance 20 exposed
Issued
May 9, 2012
Penalty
Initial $4,200 · Current $2,310 Reduced
29 CFR 1910.106(e)(5)(i): Portable fire extinguishment and control equipment were not provided in such quantities and types as needed for the special hazards of operation and storage.    a. G2 Revolution, LLC located at 200 Stanford Parkway in Findlay, Ohio:  On or about November 18, 2011, the employer did not ensure fire control equipment was functioning properly.  The employer had a sprinkler system installed in the building but the system was not hooked up to a water source.
Recent events (2)
  • — I (S) $2310
  • — Z (S) $4200

View G2 Revolution LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331095018.