Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: UTEK FRAMING, INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of UTEK FRAMING, INC in 4 TH AND 48TH STREET, GREAT FALLS, MT 59402 (NAICS 238130). OSHA activity number 331096123.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Utek Framing, INC — free Get an email when a new federal OSHA severe-injury report for Utek Framing, INC is published. One employer, no account, unsubscribe in one click.
Establishment
UTEK FRAMING, INC
Site address
4 TH AND 48TH STREET
City
GREAT FALLS
State
MT
ZIP
59402
Mailing
P.O. BOX 3148, MESQUITE, NV 89024
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
10
Ownership type
A

3 citations on file for this inspection.

1926.501 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 27, 2012
Abate by
Jan 30, 2012
Penalty
Initial $4,200 · Current $4,200
29 CFR 1926.501(b)(1): "Unprotected sides and edges." Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.      1) On or about November 30, 2011 and at times prior thereto, employees were exposed to a fall of approximately 30 feet to the ground below while conducting carpentry work such as but not limited to sheathing without fall protection in use.
Recent events (1)
  • — Z (S) $4200

1926.503 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 27, 2012
Abate by
Jan 30, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(1): The employer shall provide a training program for each employee who might be exposed to fall hazards. The program did not enable each employee to recognize the hazards of falling and did not train each employee in the procedures to be followed in order to minimize these hazards.    1) On or about November 30, 2011 and at times prior thereto, employees were not trained to recognize when or how to use fall protection while exposed to a fall of approximately 30 feet to frozen ground below.
Recent events (1)
  • — Z (S) $0

1926.1052 C01

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 27, 2012
Abate by
Jan 30, 2012
Penalty
Initial $1,800 · Current $1,800
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, was not equipped with at least one hand rail.    1) On or about November 30, 2011 and at times prior thereto, employees exposed to a fall while using stairs to access the second and third floor which were not equipped with a handrail.
Recent events (1)
  • — Z (S) $1800

View Utek Framing, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331096123.