Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: ACC AIR

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ACC AIR in 542 WEST RTE. 8 STE. 101, BARRIGADA, GU 96913 (NAICS 238220). OSHA activity number 331096339.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ACC AIR for free Get an email when a new federal OSHA severe-injury report for ACC AIR is published. One employer, no account, unsubscribe in one click.
Establishment
ACC AIR
Site address
542 WEST RTE. 8 STE. 101
City
BARRIGADA
State
GU
ZIP
96913
Mailing
542 WEST RTE. 8 STE. 201, BARRIGADA, GU 96913
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
6
Ownership type
Private (A)

2 citations on file for this inspection.

1926.1053 B04

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 26, 2012
Penalty
Initial $1,800 · Current $1,350 Reduced
29 CFR 1926.1053(b)(4): Ladders were used for purposes other than the purposes for which they were designed:    Outside the ACC Air store, an employee was using a 12' Werner fiberglass stepladder in the folded position, with the metal spreader or locking device in the closed position. Employee was exposed to fall hazards.
Recent events (2)
  • · I (S) $1350
  • · Z (S) $1800

1926.1060 A

Other-than-serious 1 instance 1 exposed
Issued
Mar 26, 2012
Abate by
Apr 16, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would train each employee in the procedures to be followed to minimize hazards related to ladders and stairways:    Outside the ACC Air store, an employee was using a 12' Werner fiberglass stepladder in the folded position. Employee did not receive training in hazard recognition and proper procedures to minimize hazards related to ladders.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 331096339.