LA CROSSE, WI ·
OSHA Inspection: PACAL INDUSTRIES, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PACAL INDUSTRIES, LLC in 400 CAR STREET, LA CROSSE, WI 54603 (NAICS 331210). OSHA activity number 331096719.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PACAL INDUSTRIES, LLC
- Site address
- 400 CAR STREET
- City
- LA CROSSE
- State
- WI
- ZIP
- 54603
- Mailing
- 400 CAR STREET, LA CROSSE, WI 54603
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331210
- Employees
- 94
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.37 B06
- Issued
- Mar 30, 2012
- Abate by
- Apr 6, 2012
- Penalty
- Initial $2,525 · Current $1,010 Reduced
General-duty citation text
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color. The exit sign at the designated emergency exit door at the ramp at Building B was not back lighted.
Recent events (2)
- · I (S) $1010
- · Z (S) $2524.5
1910.147 D04 I
- Issued
- Mar 30, 2012
- Abate by
- Apr 13, 2012
- Penalty
- Initial $4,208 · Current $2,945 Reduced
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees. a) An employee entered the envelope of movement of the Fanuc Robot #1 in Building A, without a remote control teach pendant, in order to access a control panel, but failed to lock out the power source of the robot. b) Employees were routinely entering the envelope of movement of robots in Building A in order to perform end of week cleaning, but failed to lockout the power source of the robots.
Recent events (2)
- · I (S) $2945
- · Z (S) $4207.5
1910.242 B
- Issued
- Mar 30, 2012
- Abate by
- Apr 4, 2012
- Penalty
- Initial $3,366 · Current $1,345 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: The compressed air coming from the air wand used to clear blasting media out of the blaster in Building C had not been reduced to less than 30 p.s.i..
Recent events (2)
- · I (S) $1345
- · Z (S) $3366
More inspections at Pacal Industries, LLC