Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,249Inspections Most recent open 2026-08-20 Last loaded 2026-08-24

OSHA Inspection: CYCLONE DRILLING INC.

Programmed Related inspection · Safety discipline

On , OSHA opened a programmed Related safety inspection of CYCLONE DRILLING INC. in SEC-5, TWN-157N, RNG-98W, RAY, ND 58849 (NAICS 211111). OSHA activity number 331097840.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cyclone Drilling INC. for free Get an email when a new federal OSHA severe-injury report for Cyclone Drilling INC. is published. One employer, no account, unsubscribe in one click.
Site address
SEC-5, TWN-157N, RNG-98W
City
RAY
State
ND
ZIP
58849
Mailing
P.O. BOX 908, GILLETTE, WY 82717
Inspection type
Programmed Related (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
211111
Employees
14
Ownership type
Private (A)

17 citations on file for this inspection.

5(a)(1)

Other-than-serious 1 instance 6 exposed
Issued
Apr 2, 2012
Abate by
Apr 3, 2012
Penalty
Initial $5,500 · Current $5,500
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck-by, crushing, and amputation hazards from improperly erected rig superstructure and improperly assembled tongs.      a) On or about October 29, 2011 and at times prior, Cyclone Drilling Inc did not ensure that employees were protected from struck-by, crushing, and amputation hazards.      1.  Employees were exposed to structural collapse due to several connecting pins not being installed during the erection of the rig substructure.    2.  Employees were exposed to mechanical faillure while operating the tongs on the rig floor.  The tongs were assembled using bolts instead of proper sized pins and keepers.
Recent events (2)
  • · I (O) $5500
  • · Z (S) $5500

1910.24 F

Deleted Serious Gravity 1 1 instance 7 exposed
Issued
Apr 2, 2012
Abate by
Apr 5, 2012
Penalty
Initial $3,300 · Current $0 Reduced
29 CFR 1910.24(f):  Rise height and tread width were not uniform throughout any flight of stairs including any foundation structure used as one or more treads of the stairs:      a) On or about October 29, 2011, and at times prior, Cyclone Drilling Inc. did not ensure that employees were protected from trip and fall hazards.  The stairs leading up to the doghouse had a couple of treads which were bent making the rise not uniform on all steps.
Recent events (2)
  • · I (S) $0
  • · Z (S) $3300

1910.157 C01

Deleted Serious Gravity 5 1 instance 7 exposed
Issued
Apr 2, 2012
Abate by
Apr 3, 2012
Penalty
Initial $4,400 · Current $0 Reduced
29 CFR 1910.157(c)(1):  Employer did not provide portable fire extinguishers which were mounted, located, and identified, so as to be readily accessible for emplooyee use:    a) On or about October 29, 2011, and at times prior, Cyclone Drilling Inc did not ensure that employees were protected from fire hazards.  Portable fire extinguishers in the mixing area were mounted in a bracket which would not allow for easy fast removal of the extinguisher.
Recent events (2)
  • · I (S) $0
  • · Z (S) $4400

1910.157 C04

Other-than-serious 1 instance 7 exposed
Issued
Apr 2, 2012
Abate by
Apr 3, 2012
Penalty
Initial $0 · Current $2,200
29 CFR 1910.157(c)(4):  Portable fire extinguishers were not maintained in a fully charged and operable condition:    a) On or about October 29, 2011, and at times prior, Cyclone Drilling Inc did not ensure that employees were protected from fire hazards.  Portable fire extinguishers were found, which had broken and bent pins, that could not be pulled to activate the extinguisher.
Recent events (2)
  • · I (O) $2200
  • · Z (S) $0

1910.157 E02

Deleted Serious Gravity 5 1 instance 7 exposed
Issued
Apr 2, 2012
Abate by
Apr 3, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2):  Portable fire extinguishers were not visually inspected at least monthly:      a) On or about October 29, 2011, and at times prior, Cyclone Drilling Inc. did not ensure that employees were protected from fire hazards.  The portable fire extinguishers had not been visually inspected monthly.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.219 C02 I

Other-than-serious 1 instance 7 exposed
Issued
Apr 2, 2012
Abate by
Apr 5, 2012
Penalty
Initial $4,400 · Current $2,200 Reduced
29 CFR 1910.219(c)(2)(i):  All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting:    a) On or about October 29, 2011, and at times prior, Cyclone Drilling Inc. did not ensure that employees were protected from moving mechanical parts.  The pony rods in the mud pumps area were inadequately guarded.  The top spread metal had been cut open to allow for easy access during maintenance operations.
Recent events (2)
  • · I (O) $2200
  • · Z (S) $4400

1910.303 B01

Deleted Serious Gravity 10 7 exposed
Issued
Apr 2, 2012
Abate by
Apr 5, 2012
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.303(b)(1):  Examination.  Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees.  The employer did not inspect electrical equipment to ensure the safety of the equipment pursuant to the considerations in sections (i) through (viii) of 29 CFR 1910.303(b)(1):    a) On or about October 29, 2011, and at times prior, Cyclone Drilling Inc. did not ensure that employees were protected from electrical hazards.  The electrical systems were not examined, using the criteria of sections (i) through (viii) of 29 CFR 1910.303(b)(1), to assure they were free from recognized hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $7000

1910.303 F01

Other-than-serious 1 instance 7 exposed
Issued
Apr 2, 2012
Abate by
Apr 5, 2012
Penalty
Initial $0 · Current $3,500
29 CFR 1910.303(f)(1):  Each disconnecting means required by Subpart S of Part 1910 for motors and appliances was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:    a) On or about October 29, 2011, and at times prior, Cyclone Drilling Inc. did not ensure that employees were protected from electrical hazards.  The breakers in the transformer trailer were not legibly labeled.
Recent events (2)
  • · I (O) $3500
  • · Z (S) $0

1910.305 A02 XI

Deleted Serious Gravity 10 1 instance 7 exposed
Issued
Apr 2, 2012
Abate by
Apr 5, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(a)(2)(xi): Cable assemblies and flexible cords and cables were not supported in place at intervals that ensure that they will be protected from physical damage.     a) On or about October 29, 2011, and at times prior, Cyclone Drilling Inc. did not ensure that employees were protected from electrical hazards.  Flexible cords throughout the site were lying in the mud.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.305 B02

Other-than-serious 1 instance 5 exposed
Issued
Apr 2, 2012
Abate by
Apr 5, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i):  Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:    a) On or about October 29, 2011, and at times prior, Cyclone Drilling Inc. did not ensure that employees were protected from electrical hazards.  The diesel pump, supplying the mud tanks, had the cover taken off of the switch box.
Recent events (2)
  • · I (O) $0
  • · Z (S) $0

1910.305 E01

Deleted Serious Gravity 10 1 instance 5 exposed
Issued
Apr 2, 2012
Abate by
Apr 5, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(e)(1):  Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in damp or wet locations were not installed to prevent moisture or water from entering and accumulating within the enclosures:    a) On or about October 29, 2011, and at times prior, Cyclone Drilling Inc did not ensure that employees were protected from electrical hazards.  Boxes and panel boards along with flexible cords that were not rated for wet or damp locations were used on the companyman, toolpusher and mancamp trailers.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.305 G02 II

Deleted Serious Gravity 10 1 instance 7 exposed
Issued
Apr 2, 2012
Abate by
Apr 5, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(ii):  Hard-service cord and junior hard-service cord No. 14 and larger were repaired by splicing, which did not retain the insulation, outer sheath properties, and usage characteristics of the cord that was spliced:  Note:  Hard service flexible cords No. 12 or larger may be spliced if the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced.    a) On or about October 29, 2011, and at times prior, Cyclone Drilling Inc. did not ensure that employees were protected from electrical hazards.  The cords were field spliced and then wrapped with electrical tape.  This practice does not retain the insulation and outer sheath properties to a level that meets the manufacturers specifications.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.305 G02 III

Other-than-serious 1 instance 7 exposed
Issued
Apr 2, 2012
Abate by
Apr 5, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii):  Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:    a) On or about October 29, 2011, and at times prior, Cyclone Drilling Inc. did not ensure that employees were protected from electrical hazards.  Several flexible cords located at the mud tanks and trailers had defective strain reliefs.
Recent events (2)
  • · I (O) $0
  • · Z (S) $0

1910.334 A01

Other-than-serious 1 instance 7 exposed
Issued
Apr 2, 2012
Abate by
Apr 5, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(1):  Flexible electric cords were fastened with staples or otherwise hung in such a fashion as could damage the outer jacket or insulation:    a) On or about October 29, 2011, and at times prior, Cyclone Drilling Inc. did not ensure that employees were protected from electrical hazards.  Tie wire had been used to hang electrical cords at several places on the site.
Recent events (2)
  • · I (O) $0
  • · Z (S) $0

1910.23 C01

Serious Gravity 5 1 instance 7 exposed
Issued
Apr 2, 2012
Abate by
Apr 3, 2012
Penalty
Initial $25,000 · Current $7,000 Reduced
29 CFR 1910.23(c)(1):  Open sided floor(s) or platform(s) 4 feet or more above the adjacent floor or ground level were not guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)(i) through (v):    a) On or about October 29, 2011, and at times prior, employees were exposed to falls of approximately 26 feet at the V-door.     Cyclone Drilling, Inc., was previously cited for a violation of this Occupational Safety and Health standard or its equivalent standard 1910.23(c)(1) which was contained in OSHA inspection 311214753 citation number 1 item 3 issued on 06/17/2008, and became a final order on 07/14/2008 with respect to a workplace located at Rig #15 Marla #3-35 H, Lambert, MT 59243.
Recent events (2)
  • · I (S) $7000
  • · Z (R) $25000

1910.151 C

Serious Gravity 1 1 instance 7 exposed
Issued
Apr 2, 2012
Abate by
Apr 3, 2012
Penalty
Initial $15,000 · Current $7,000 Reduced
29 CFR 1910.151(c): Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use:    a) On or about October 29, 2011, and at times prior, employees were not protected from corrosive materials, such as lime, in that the eye wash station was not functional.     Cyclone Drilling, Inc., was previously cited for a violation of this Occupational Safety and Health standard or its equivalent standard 1910.151(c) which was contained in OSHA inspection 314658196 citation number 1 item 2 issued on 11/09/2010, and became a final order on 12/17/2010 with respect to a workplace located at Federal RGU #543-24-198, Rig #29, Meeker, CO 81641.
Recent events (2)
  • · I (S) $7000
  • · Z (R) $15000

1910.142 D10

Other-than-serious 1 instance 7 exposed
Issued
Apr 2, 2012
Abate by
Apr 3, 2012
Penalty
Initial $1,000 · Current $0 Reduced
29 CFR 1910.142(d)(10): Privies and toilet rooms were not kept in a sanitary condition and cleaned at least daily:    a) On or about October 29, 2011, and at times prior, Cyclone Drilling Inc. did not ensure that employees were protected from health hazards.  The provided toilet room was not cleaned daily.
Recent events (2)
  • · I (O) $0
  • · Z (O) $1000

View Cyclone Drilling INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 331097840.