OSHA Inspection: S2K INC. DBA BARGAINLOCKS

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of S2K INC. DBA BARGAINLOCKS in 7239 WALES AVE. NW, NORTH CANTON, OH 44720 (NAICS 444130). OSHA activity number 331099085.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch S2K INC. DBA Bargainlocks for free Get an email when a new federal OSHA severe-injury report for S2K INC. DBA Bargainlocks is published. One employer, no account, unsubscribe in one click.
Site address
7239 WALES AVE. NW
City
NORTH CANTON
State
OH
ZIP
44720
Mailing
7239 WALES AVE. NW, NORTH CANTON, OH 44720
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
444130
Employees
12
Ownership type
Private (A)

6 citations on file for this inspection.

1910.24 H

Serious Gravity 1 1 instance 2 exposed
Issued
Dec 15, 2011
Abate by
Jan 31, 2012
Penalty
Initial $1,800 · Current $1,080 Reduced
29 CFR 1910.24(h): Standard railings were not provided on the open sides of all exposed stairways and stair platforms:    On 11/7/2011, the 40 inch high cement staircase, outside at the loading dock, did not have a standard handrail system.
Recent events (2)
  • · I (S) $1080
  • · Z (S) $1800

1910.157 G01

Serious Gravity 1 1 instance 12 exposed
Issued
Dec 15, 2011
Abate by
Jan 31, 2012
Penalty
Initial $1,800 · Current $1,080 Reduced
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting:    On and before 12/7/2011, employees had not received portable fire extinguisher training.
Recent events (2)
  • · I (S) $1080
  • · Z (S) $1800

1910.178 L06

Serious Gravity 1 1 instance 2 exposed
Issued
Dec 15, 2011
Abate by
Jan 31, 2012
Penalty
Initial $1,800 · Current $1,080 Reduced
29 CFR 1910.178(l)(6): The employer did not certify that each operator had been trained and evaluated as required by this paragraph (l):    On and before 12/7/2011, the employer did not certify the powered industrial vehicle operator training and evaluation.
Recent events (2)
  • · I (S) $1080
  • · Z (S) $1800

1910.178 Q07

Serious Gravity 1 1 instance 2 exposed
Issued
Dec 15, 2011
Abate by
Jan 31, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service:    On 12/7/2011, the forklift and pallet jack that is used daily did not receive the required daily inspection since 10/7/2011.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.1200 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 15, 2011
Abate by
Jan 31, 2012
Penalty
Initial $2,400 · Current $1,440 Reduced
29 CFR 1910.1200(e)(1): 29 CFR 1910.1200(e)(1):  The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    On and before 12/7/2011, the employer did not develop and establish a hazard communication program for material such as but not limited to liquified propane gas.
Recent events (2)
  • · I (S) $1440
  • · Z (S) $2400

1910.305 B01 II

Other-than-serious 1 instance 2 exposed
Issued
Dec 15, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    On 12/7/2011, the electrical toggle switch junction box for the building furnace had an unused opening in the top.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0