MENOMONIE, WI ·
OSHA Inspection: AMERICAN STRUCTURES, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of AMERICAN STRUCTURES, INC. in N4471 469TH STREET, MENOMONIE, WI 54751 (NAICS 332420). OSHA activity number 331099283.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AMERICAN STRUCTURES, INC.
- Site address
- N4471 469TH STREET
- City
- MENOMONIE
- State
- WI
- ZIP
- 54751
- Mailing
- P.O. BOX 409, MENOMONIE, WI 54751
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332420
- Employees
- 24
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 C01
- Issued
- Apr 17, 2012
- Abate by
- May 30, 2012
- Penalty
- Initial $3,000 · Current $1,800 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): Energy control program. The employer shall establish a program consisting of energy control procedures, employee training, and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine orequipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. (a) Throughout the facility; The employer did not establish an energy control program consisting of specific energy control procedures, employee training, and periodic inspections to ensure machinery or equipment was properly isolated from energy source(s).
Recent events (2)
- · I (S) $1800
- · Z (S) $3000
1910.147 C04 II
- Issued
- Apr 17, 2012
- Abate by
- May 30, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules,and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance. (a) Throughout the facility; The employer did not establish clear and specific steps to be followed in order to control the release of hazardous energy for machinery such as, but not limited to, the CNC Punch Presses (Whitney & Wiedemann), Shears (Betenbender & Ursviken), Press Brakes (Pacific & LVD), Sheet Roller, Angle Rollers, CNC Angle Punch Press, Lathes, Milling Machines (Ex-Cell-O & Bridgeport), Iron Workers (HydraCrop), and Hydraulic Saw (s-20P).
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.147 C06 I
- Issued
- Apr 17, 2012
- Abate by
- May 30, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. (a) Throughout the facility; The employer did not conduct a periodic inspection of the energy control procedure(s) at least annually to ensure lockout procedures were adequate and properly implemented.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.147 C07 I
- Issued
- Apr 17, 2012
- Abate by
- May 30, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. (a) Throughout the facility; A hazardous energy control (lockout/tagout) training program was not provided for both authorized and affected employees.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.212 A03 II
- Issued
- Apr 17, 2012
- Abate by
- Jul 12, 2012
- Penalty
- Initial $3,000 · Current $1,800 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, shall beguarded. The guarding device shall be in conformity with any appropriate standards, or, in the absence of applicable specific standards,shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operatingcycle. (a) Press Brake Area; The Pacific hydraulic press brake (s/n 6006LE) had no point of operation guarding.
Recent events (2)
- · I (S) $1800
- · Z (S) $3000
More inspections at American Structures, INC.
View American Structures, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332420)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331099283.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.