Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: A.J. MANUFACTURING INCORPORATED

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of A.J. MANUFACTURING INCORPORATED in 105 RIGGS STREET, BLOOMER, WI 54724 (NAICS 332321). OSHA activity number 331099952.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch A.J. Manufacturing Incorporated — free Get an email when a new federal OSHA severe-injury report for A.J. Manufacturing Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
105 RIGGS STREET
City
BLOOMER
State
WI
ZIP
54724
Mailing
1217 OAK STREET, BLOOMER, WI 54724
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332321
Employees
62
Ownership type
A

8 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 1 1 exposed
Issued
Feb 28, 2012
Abate by
Mar 13, 2012
Penalty
Initial $2,700 · Current $1,890 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  (a) Main production floor; Machine specific energy control procedures were not developed for machines with multiple energy sources, such as, but not limited to; Foam gun, foam press.
Recent events (2)
  • — I (S) $1890
  • — Z (S) $2700

1910.147 C06 I

Serious Gravity 1 2 exposed
Issued
Feb 28, 2012
Abate by
Mar 13, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  (a) Throughout the facility; Energy control procedures were not evaluated at least annually.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D04 I

Serious Gravity 1 1 exposed
Issued
Feb 28, 2012
Abate by
Mar 13, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:  (a) Main production floor; Employees did not isolate the stored energies of the pressurized foam and pneumatic sources while conducting servicing and/ or maintenance tasks, such as, but not limited to, cleaning of the foam gun.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A03 II

Serious Gravity 5 1 exposed
Issued
Feb 28, 2012
Abate by
Mar 20, 2012
Penalty
Initial $4,500 · Current $3,150 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  (a) Main production floor; The point of operation of the JCI Frame Punch #57 was not guarded.  (b) Main production floor; The point of operation of the JCI Corner Frame Punch #57 was not guarded.  (c) Main production floor; The point of operation of the Jet H/V band saw had 5" of unguarded blade.  (d) Main production floor; The point of operation of the Installation Punch #34 was not guarded.
Recent events (2)
  • — I (S) $3150
  • — Z (S) $4500

1910.215 B09

Serious Gravity 5 1 exposed
Issued
Feb 28, 2012
Abate by
Mar 2, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  (a) Maintenance shop; The right upper tongue of an Erco 8" bench grinder was adjusted beyond 1/4".
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 E01 I

Serious Gravity 5 1 exposed
Issued
Feb 28, 2012
Abate by
Mar 20, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven -7 feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt:  (a) Maintenance shop; The Bridgeport mill drive belts below 7 feet were partially exposed on two sides.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 C02 I

Other-than-serious 1 exposed
Issued
Feb 28, 2012
Abate by
Mar 20, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible:  (a) Employees voluntarily used respirators and were not provided with 1910.134 Appendix D information.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.252 C02 II

Other-than-serious 1 exposed
Issued
Feb 28, 2012
Abate by
Mar 28, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.252(c)(2)(ii): Mechanical ventilation provided did not meet the minimum rate of 2,000 cubic feet (57 m3) per minute per welder:  (a) Main shop floor; Air velocity at the welding booth next to the robot welder was measured at 0 foot per minute at the operators station with the welding fume ventilation system running.