On , OSHA opened a complaint health inspection of A.J. MANUFACTURING INCORPORATED in 105 RIGGS STREET, BLOOMER, WI 54724 (NAICS 332321). OSHA activity number 331099952.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- A.J. MANUFACTURING INCORPORATED
- Site address
- 105 RIGGS STREET
- City
- BLOOMER
- State
- WI
- ZIP
- 54724
- Mailing
- 1217 OAK STREET, BLOOMER, WI 54724
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332321
- Employees
- 62
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.147 C04 I
- Issued
- Feb 28, 2012
- Abate by
- Mar 13, 2012
- Penalty
- Initial $2,700 · Current $1,890 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) Main production floor; Machine specific energy control procedures were not developed for machines with multiple energy sources, such as, but not limited to; Foam gun, foam press.
Recent events (2)
- — I (S) $1890
- — Z (S) $2700
1910.147 C06 I
- Issued
- Feb 28, 2012
- Abate by
- Mar 13, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a) Throughout the facility; Energy control procedures were not evaluated at least annually.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D04 I
- Issued
- Feb 28, 2012
- Abate by
- Mar 13, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: (a) Main production floor; Employees did not isolate the stored energies of the pressurized foam and pneumatic sources while conducting servicing and/ or maintenance tasks, such as, but not limited to, cleaning of the foam gun.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A03 II
- Issued
- Feb 28, 2012
- Abate by
- Mar 20, 2012
- Penalty
- Initial $4,500 · Current $3,150 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): (a) Main production floor; The point of operation of the JCI Frame Punch #57 was not guarded. (b) Main production floor; The point of operation of the JCI Corner Frame Punch #57 was not guarded. (c) Main production floor; The point of operation of the Jet H/V band saw had 5" of unguarded blade. (d) Main production floor; The point of operation of the Installation Punch #34 was not guarded.
Recent events (2)
- — I (S) $3150
- — Z (S) $4500
1910.215 B09
- Issued
- Feb 28, 2012
- Abate by
- Mar 2, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: (a) Maintenance shop; The right upper tongue of an Erco 8" bench grinder was adjusted beyond 1/4".
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 E01 I
- Issued
- Feb 28, 2012
- Abate by
- Mar 20, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven -7 feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt: (a) Maintenance shop; The Bridgeport mill drive belts below 7 feet were partially exposed on two sides.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 C02 I
- Issued
- Feb 28, 2012
- Abate by
- Mar 20, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: (a) Employees voluntarily used respirators and were not provided with 1910.134 Appendix D information.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.252 C02 II
- Issued
- Feb 28, 2012
- Abate by
- Mar 28, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.252(c)(2)(ii): Mechanical ventilation provided did not meet the minimum rate of 2,000 cubic feet (57 m3) per minute per welder: (a) Main shop floor; Air velocity at the welding booth next to the robot welder was measured at 0 foot per minute at the operators station with the welding fume ventilation system running.