OSHA Inspection: NATIONAL OILWELL - VARCO FLUID CONTROL

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of NATIONAL OILWELL - VARCO FLUID CONTROL in SEC-33T, TWN-157N, RNG-90W, RAY, ND 58849 (NAICS 211111). OSHA activity number 331100644.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch National Oilwell - Varco Fluid Control — free Get an email when a new federal OSHA severe-injury report for National Oilwell - Varco Fluid Control is published. One employer, no account, unsubscribe in one click.
Site address
SEC-33T, TWN-157N, RNG-90W
City
RAY
State
ND
ZIP
58849
Mailing
6421 115TH AVE NW, RAY, ND 58849
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
211111
Employees
2
Ownership type
A

4 citations on file for this inspection.

1910.24 F

Deleted Serious Gravity 1 1 instance 4 exposed
Issued
Mar 26, 2012
Abate by
Mar 29, 2012
Penalty
Initial $3,300 · Current $0 Reduced
29 CFR 1910.24(f):  Rise height and tread width were not uniform throughout any flight of stairs including any foundation structure used as one or more treads of the stairs:      a) On or about October 31, 2011, and at times prior, employees were exposed to slips and trips in that, the stairs located at the doghouse were bent resulting in the treads not being uniform.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3300

1910.219 C02 I

Other-than-serious 1 instance 4 exposed
Issued
Mar 26, 2012
Abate by
Mar 29, 2012
Penalty
Initial $5,500 · Current $2,750 Reduced
29 CFR 1910.219(c)(2)(i):   All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting:  requires:    a) On or about October 31, 2011, and at times prior, National Oilwell-Varco Fluid Control, did not protect their employees from injury in that, the transfer pump shaft was not guarded.
Recent events (2)
  • — I (O) $2750
  • — Z (S) $5500

1910.303 B01

Other-than-serious 1 instance 4 exposed
Issued
Mar 26, 2012
Abate by
Mar 27, 2012
Penalty
Initial $7,000 · Current $2,750 Reduced
29 CFR 1910.303(b)(1):   Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:      (a) On or about October 31, 2011, and at times prior, National Oilwell-Varco Fluid Control did not protect their employees from injury in that, the electrical equipment was not inspected prior to use.
Recent events (2)
  • — I (O) $2750
  • — Z (S) $7000

1910.305 B01

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
Mar 26, 2012
Abate by
Mar 29, 2012
Penalty
Initial $0 · Current $0