RAY, ND —
OSHA Inspection: NATIONAL OILWELL - VARCO FLUID CONTROL
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of NATIONAL OILWELL - VARCO FLUID CONTROL in SEC-33T, TWN-157N, RNG-90W, RAY, ND 58849 (NAICS 211111). OSHA activity number 331100644.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NATIONAL OILWELL - VARCO FLUID CONTROL
- Site address
- SEC-33T, TWN-157N, RNG-90W
- City
- RAY
- State
- ND
- ZIP
- 58849
- Mailing
- 6421 115TH AVE NW, RAY, ND 58849
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 211111
- Employees
- 2
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.24 F
- Issued
- Mar 26, 2012
- Abate by
- Mar 29, 2012
- Penalty
- Initial $3,300 · Current $0 Reduced
General-duty citation text
29 CFR 1910.24(f): Rise height and tread width were not uniform throughout any flight of stairs including any foundation structure used as one or more treads of the stairs: a) On or about October 31, 2011, and at times prior, employees were exposed to slips and trips in that, the stairs located at the doghouse were bent resulting in the treads not being uniform.
Recent events (2)
- — I (S) $0
- — Z (S) $3300
1910.219 C02 I
- Issued
- Mar 26, 2012
- Abate by
- Mar 29, 2012
- Penalty
- Initial $5,500 · Current $2,750 Reduced
General-duty citation text
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: requires: a) On or about October 31, 2011, and at times prior, National Oilwell-Varco Fluid Control, did not protect their employees from injury in that, the transfer pump shaft was not guarded.
Recent events (2)
- — I (O) $2750
- — Z (S) $5500
1910.303 B01
- Issued
- Mar 26, 2012
- Abate by
- Mar 27, 2012
- Penalty
- Initial $7,000 · Current $2,750 Reduced
General-duty citation text
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees: (a) On or about October 31, 2011, and at times prior, National Oilwell-Varco Fluid Control did not protect their employees from injury in that, the electrical equipment was not inspected prior to use.
Recent events (2)
- — I (O) $2750
- — Z (S) $7000
1910.305 B01
- Issued
- Mar 26, 2012
- Abate by
- Mar 29, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) On or about October 31, 2011, and at times prior, National Oilwell-Varco Fluid Control, did not protect their employees from injury in that, the fly ash electrical panel box had openings.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 211111)
More inspections in ND
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331100644.