OSHA Inspection: ROCKFORD PROCESS CONTROL, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ROCKFORD PROCESS CONTROL, INC. in 2020 7TH STREET, ROCKFORD, IL 61104 (NAICS 332116). OSHA activity number 331101931.

Watch Rockford Process Control, INC. — free Get an email when a new federal OSHA severe-injury report for Rockford Process Control, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2020 7TH STREET
City
ROCKFORD
State
IL
ZIP
61104
Mailing
2020 7TH STREET, ROCKFORD, IL 61104
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332116
Employees
74
Ownership type
A

4 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 2 instances 2 exposed
Issued
Feb 21, 2012
Abate by
Mar 22, 2012
Penalty
Initial $2,800 · Current $1,960 Reduced
29 CFR 1910.212(a)(1):     One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    On the small assembly machine, the pinner unit had 2 nip points that were not guarded, one at the feeder and one at the pusher.    Abatement documentation is required for this item in accordance with 29 CFR 1903.19(c).
Recent events (2)
  • — I (S) $1960
  • — Z (S) $2800

1910.217 C05 I

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 21, 2012
Abate by
Apr 3, 2012
Penalty
Initial $3,500 · Current $2,450 Reduced
29 CFR 1910.217(c)(5)(i):     Mechanical power press(es) where the operator feeds or removes parts by placing one or both hands in the point of operation, and a two hand control, presence sensing device, or type B gate or movable barrier guard is used, were not equipped with a brake monitor:    The Niagara 200 ton, #169, part revolution mechanical power press was not equipped with a brake monitor.    No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $2450
  • — Z (S) $3500

1910.147 C06 I

Other-than-serious 1 instance 18 exposed
Issued
Feb 21, 2012
Abate by
Mar 22, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i):     The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    Rockford Process  Control did not conduct a periodic inspection of their lockout program.    Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.217 E01 I

Other-than-serious 1 instance 1 exposed
Issued
Feb 21, 2012
Abate by
Mar 22, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.217(e)(1)(i):     A program of periodic and regular inspections of mechanical power press(es) was not established and followed to insure that all parts, auxiliary equipment and safeguards were in a safe operating condition and adjustment:    Rockford Process Control did not establish a program of periodic and regular inspections of their mechanical power presses.    Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d)