COLUMBUS, OH ·
OSHA Inspection: AQUA SCIENCE, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of AQUA SCIENCE, INC. in 1601 WOODLAND AVENUE, COLUMBUS, OH 43219 (NAICS 325998). OSHA activity number 331103374.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AQUA SCIENCE, INC.
- Site address
- 1601 WOODLAND AVENUE
- City
- COLUMBUS
- State
- OH
- ZIP
- 43219
- Mailing
- 1601 WOODLAND AVENUE, COLUMBUS, OH 43219
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325998
- Employees
- 31
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.212 A01
- Issued
- Dec 20, 2011
- Abate by
- Jan 19, 2012
- Penalty
- Initial $2,975 · Current $2,083 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips andsparks. Examples of guarding methods are-barrier guards, two-hand tripping devices, electronic safety devices, etc.: a. In the mixing area, the shaft for the Lightnin mixer (model: N33 AG; S/N: 80-920715) on the 225 gallon tank was not guarded. b. In the mixing area, the shaft for the Lightnin mixer (model: N33 AR-33; S/N: 80-920714) on the 200 gallon tank was not guarded. c. In the mixing area, the shaft for the Lightnin mixer on the 25 gallon tank was not guarded.
Recent events (2)
- · I (S) $2082.5
- · Z (S) $2975