COLBY, WI —
OSHA Inspection: COLBY METAL INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of COLBY METAL INC. in 701 INDUSTRIAL DR., COLBY, WI 54421 (NAICS 332999). OSHA activity number 331106740.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COLBY METAL INC.
- Site address
- 701 INDUSTRIAL DR.
- City
- COLBY
- State
- WI
- ZIP
- 54421
- Mailing
- PO BOX 466, COLBY, WI 54421
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 61
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.107 B05 IV
- Issued
- Jun 11, 2012
- Abate by
- Oct 18, 2012
- Penalty
- Initial $2,142 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.107(b)(5)(iv): Spaces within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers: a.) On or about 12/28/2011, the dry filter type spray booth for electrostatic paint application was not equipped with automatic sprinklers or an alternate system for fire protection on either the upstream or the downstream areas. Abatement Certification and Documentation required.
Recent events (2)
- — I (S) $1500
- — Z (S) $2142
1910.107 B09
- Issued
- Jun 11, 2012
- Abate by
- Jun 12, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(b)(9): A clear space of not less than 3 feet on all sides was not kept free from storage or combustible construction: a.) On or about 12/28/2011, cardboard boxes were stored adjacent to the powder spray booth. Abatement Certification and Documentation required.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.107 C04
- Issued
- Jun 11, 2012
- Abate by
- Sep 5, 2012
- Penalty
- Initial $1,607 · Current $1,120 Reduced
General-duty citation text
29 CFR 1910.107(c)(4): Electrical wiring and equipment did not conform to the provisions of 29 CFR 1910.107(c) and was not otherwise in accordance with 29 CFR Subpart S, in that Class II, Division 1 or 2 approved equipment and wiring was not used where deposits of combustible residues could readily accumulate: a.) On or about 12/28/2011, powder residue was noted on the floor outside the booth and accumulated on a plug-in connection for equipment in the powder spray booth. This plug-in and other electrical connections immediately outside the booth were not approved for Class II, Division 1 or 2 locations. Abatement Certification and Documentation required.
Recent events (2)
- — I (S) $1120
- — Z (S) $1606.5
1910.107 L04 I
- Issued
- Jun 11, 2012
- Abate by
- Jul 24, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(l)(4)(i): All areas were not kept free of the accumulation of powder coating dust: a.) On or about 12/28/2011, there was spray powder residue located on the floor outside the spray booth. Abatement Certification and Documentation required.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.307 C02 I
- Issued
- Jun 11, 2012
- Abate by
- Sep 5, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.307(c)(2)(i): Equipment was not approved for the class of location and for the ignitable or combustible properties of the specific gas, vapor, dust, or fiber that would be present: a.) On or about 12/28/2011, spray powder residue was noted on the floor outside the booth and accumulated on a plug-in connection for equipment in the powder spray booth. The spray powder is identified by the manufacturer as having the potential for explosive condition. The plug-in and other electrical connections immediately outside the booth were not approved for Class II, Division 1 or 2 locations. Abatement Certification and Documentation required.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.107 L07 V
- Issued
- Jun 11, 2012
- Abate by
- Jul 24, 2012
- Penalty
- Initial $3,213 · Current $2,250 Reduced
General-duty citation text
29 CFR 1910.107(l)(7)(v): The electrical equipment was not interlocked with the ventilation system so that the equipment could not be operated unless the ventilation fans were in operation: a.) On or about 12/28/2011, the powder spray booth was operated without an interlock to ensure that application could only occur while the ventilation was operational. Abatement Certification and Documentation required.
Recent events (2)
- — I (S) $2250
- — Z (S) $3213
1910.1200 F05 I
- Issued
- Jun 11, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein: a.) On or about 12/28/2011, a spray bottle of Simple Green All-Purpose Cleaner which contains 2-Butoxyethanol had a label that was illegible, such that the identifying name was unclear. Abatement Certification or Documentation not required.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 F05 I
- Issued
- Jun 11, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein: a.) On or about 12/28/2011, a spray bottle of Simple Green All-Purpose Cleaner which contains 2-Butoxyethanol had a label that was illegible, such that the hazard warning advising possible skin or respiratory irritation was unclear. Abatement Certification or Documentation not required.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Colby Metal INC.
View Colby Metal INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332999)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331106740.