CHICAGO, IL —
OSHA Inspection: ZERA CONSTRUCTION COMPANY, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ZERA CONSTRUCTION COMPANY, INC. in ST. PAUL CATHOLIC CHURCH 2127 WEST 22ND PLACE, CHICAGO, IL 60608 (NAICS 236220). OSHA activity number 331106997.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ZERA CONSTRUCTION COMPANY, INC.
- Site address
- ST. PAUL CATHOLIC CHURCH 2127 WEST 22ND PLACE
- City
- CHICAGO
- State
- IL
- ZIP
- 60608
- Mailing
- 7800 LEHIGH AVENUE, NILES, IL 60714
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 47
- Ownership type
- A
Citations
14 citations on file for this inspection.
1926.403 B02
- Issued
- Feb 7, 2012
- Abate by
- Feb 8, 2012
- Penalty
- Initial $3,080 · Current $1,540 Reduced
General-duty citation text
29 CFR 1926.403(b)(2): installation and use. Listed, labeled, or certified equipment shall be installed and used in accordance with instructions included in the listing, labeling, or certification. a. On or about December 23, 2011 - at the above addressed jobsite, employees used a relocatable power tap for temporary lighting, thereby exposing employees to the hazards associated with electrical shock.
Recent events (2)
- — I (S) $1540
- — Z (S) $3080
1926.403 I02 I
- Issued
- Feb 7, 2012
- Abate by
- Feb 8, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.403(i)(2)(i): Except as required or permitted elsewhere in this subpart, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by cabinets or other forms of enclosures, or by any of the following means: a. On or about December 23, 2011 - at the above addressed jobsite, employees working on the basement renovation were exposed to open electrical junction boxes which contained 110 Volt live electric circuits, thereby exposing employees to the hazards associated with electrical shock.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.403 I02 I D
- Issued
- Feb 7, 2012
- Abate by
- Feb 8, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.403(i)(2)(i)(D): By elevation of 8 feet (2.44 m) or more above the floor or other working surface and so installed as to exclude unqualified persons. a. On or about December 23, 2011 - at the above addressed jobsite, employees working on the basement renovation were exposed to open electrical junction boxes which contained 110 Volt live electric circuits which were installed/elevated at heights ranging from 7' to 7'5", thereby exposing the employees to the hazards associated with electrical shock.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.405 A02 II E
- Issued
- Feb 7, 2012
- Abate by
- Feb 8, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(E): All lamps for general illumination shall be protected from accidental contact or breakage. Metal-case sockets shall be grounded. a. On or about December 23, 2011 - at the above addressed jobsite, employees working on a basement renovation were exposed to electrical hazards due to temporary lighting not being protected from accidental contact or breakage.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 A06
- Issued
- Feb 7, 2012
- Abate by
- Feb 8, 2012
- Penalty
- Initial $5,390 · Current $2,695 Reduced
General-duty citation text
29 CFR 1926.451(a)(6): Scaffolds shall be designed by a qualified person and shall be constructed and loaded in accordance with that design. a. On or about December 23, 2011 - at the above addressed jobsite, employees were constructing a wooden canopy structure while working on a self made scaffold, approximately eighteen (18') feet above the ground, that was not designed by a qualified person, thereby exposing employees to fall hazards.
Recent events (2)
- — I (S) $2695
- — Z (S) $5390
1926.451 B02
- Issued
- Feb 7, 2012
- Abate by
- Feb 8, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(b)(2): each scaffold platform and walkway shall be at least 18 inches (46 cm) wide. a. On or about December 23, 2011 - at the above addressed jobsite, employees were constructing a wooden canopy structure while standing on a platform approximately eighteen (18') feet above the ground. The scaffold platform was not at least 18 inches wide, thereby exposing employees to the hazards associated with falls.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 E01
- Issued
- Feb 7, 2012
- Abate by
- Feb 8, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall beused. Crossbraces shall not be used as a means of access. a. On or about December 23, 2011 - at the above addressed jobsite, employees constructing a wooden canopy structure while working on a self made scaffold, approximately eighteen (18') feet above the ground, were not provided with a safe means of access to the scaffold platform, thereby exposing employees to the hazards associated with falls.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 G01
- Issued
- Feb 7, 2012
- Abate by
- Feb 8, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. a. On or about December 23, 2011 - at the above addressed jobsite, employees constructing a wooden canopy structure while working on a self made scaffold, approximately eighteen (18') feet above the ground, were exposed to injuries from falls due to the lack of fall protection.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.454 A
- Issued
- Feb 7, 2012
- Abate by
- Apr 10, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.454(a): The employer shall have each employee who performs work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to controlor minimize those hazards. The training shall include the following areas, as applicable: a. On or about December 23, 2011 - at the above addressed jobsite, employees constructing a wooden canopy structure while working on a self made scaffold approximately eighteen (18') feet above the ground, were not trained to recognize the hazards associated with scaffolding, thereby exposing employees to the hazards associated with falls.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.652 A01
- Issued
- Feb 7, 2012
- Abate by
- Feb 8, 2012
- Penalty
- Initial $5,390 · Current $2,695 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section except when: a. On or about December 23, 2011 - at the above addressed jobsite, employees were erecting a canopy in an excavation approximately sixteen (16') feet in depth that was not provided with an adequate protective system, thereby exposing the employees to the hazards associated with cave-ins.
Recent events (2)
- — I (S) $2695
- — Z (S) $5390
1926.1053 B04
- Issued
- Feb 7, 2012
- Abate by
- Feb 8, 2012
- Penalty
- Initial $5,390 · Current $2,695 Reduced
General-duty citation text
29 CFR 1926.1053(b)(4): Ladders shall be used only for the purpose for which they were designed. a. On or about December 23, 2011 - at the above addressed jobsite, employees used a ten (10') foot step ladder as means of support for a self made scaffold, thereby exposing employees to the hazards associated with falls. b. On or about December 23, 2011 - at the above addressed jobsite, employees were using a horizontally placed fiberglass extension ladder as a scaffold platform approximately eighteen (18') feet above the ground, thereby exposing employees to the hazards associated with falls. c. On or about December 23, 2011 - at the above addressed jobsite, a ten (10') foot step ladder was altered by affixing a 4x4 piece of lumber to one of the footings of the ladder, thereby exposing employees to the hazards associated with falls. d. On or about December 23, 2011 - at the above addressed jobsite, employees failed to use the metal spreader or locking device which was provided on the ten (10') foot step ladder to hold the front and back sections in an open position when the ladder is being used, thereby exposing employees to the hazards associated with falls.
Recent events (2)
- — I (S) $2695
- — Z (S) $5390
1926.1053 B15
- Issued
- Feb 7, 2012
- Abate by
- Feb 8, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(15): Ladders shall be inspected by a competent person for visible defects on a periodic basis and after any occurrence that could affect their safe use. a. On or about December 23, 2011 - at the above addressed jobsites, employees were using a wooden ladder which had missings rungs. A competent person failed to inspect the ladder and identify the hazard, thereby exposing employees to the hazards associated with falls. b. On or about December 23, 2011 - at the above addressed jobsite, employees were using a ten (10') foot step ladder which was altered by affixing a 4x4 piece of lumber to one of the footings of the ladder. A competent person failed to inspect the ladder and identify the hazard, thereby exposing employees to the hazards associated with falls.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B16
- Issued
- Feb 7, 2012
- Abate by
- Feb 8, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with "Do Not Use" or similar language, and shall be withdrawn from service until repaired. a. On or about December 23, 2011 - at the above addressed jobsites, employees were using a wooden ladder which had missings rungs, thereby exposing employees to the hazards associated with falls.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1060 A
- Issued
- Feb 7, 2012
- Abate by
- Feb 29, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1060(a): The employer shall provide a training program for each employee using ladders and stairways, as necessary. The program shall enable each employee to recognize hazards related to ladders and stairways, and shall train each employee in the procedures to be followed to minimize these hazards. a. On or about December 23, 2011 - at the above addressed jobsite, the employer failed to provide a training program for each employee who is required to use a ladder, thereby exposing employees to the hazards associated with falls.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Zera Construction Company, INC.
View Zera Construction Company, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331106997.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.