Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PERFORMIX NUTRITION SYSTEMS, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PERFORMIX NUTRITION SYSTEMS, LLC in 1811 E KARCHER RD, NAMPA, ID 83687 (NAICS 311119). OSHA activity number 331107839.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Performix Nutrition Systems, LLC — free Get an email when a new federal OSHA severe-injury report for Performix Nutrition Systems, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1811 E KARCHER RD
City
NAMPA
State
ID
ZIP
83687
Mailing
1811 E KARCHER RD, NAMPA, ID 83687
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311119
Employees
63
Ownership type
A

5 citations on file for this inspection.

1910.23 A02

Serious Gravity 5 2 instances 1 exposed
Issued
Mar 27, 2012
Abate by
Apr 17, 2012
Penalty
Initial $2,100 · Current $1,150 Reduced
29 CFR 1910.23(a)(2): Ladderway floor opening(s) or platform(s) were not guarded by a standard railing with standard toeboard(s) on all exposed sides (except at the entrance to opening) with passage through the railing either provided with a swinging gate or so offset that a person could walk directly into the opening:      (a)	Bulk tank ladder to Production roof: On 12/29/2011 and at times prior thereto, an intermediate ladder landing at 9 6 high was not protected to prevent a worker from walking directly into the opening.    (b)	 Bulk tank ladder to Production roof: On 12/29/2011 and at times prior thereto, the ladder opening to the top of the tank at 16 high was not protected to prevent a worker from walking directly into the opening.    Note: Abatement certification IS required for this item.
Recent events (2)
  • — I (S) $1150
  • — Z (S) $2100

1910.23 A07

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 27, 2012
Abate by
Apr 17, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.23(a)(7): Every temporary floor opening did not have standard railings:    (a)	Customer Equipment Mezzanine: On 12/29/2011 and at times prior thereto, the standard railing was missing a section of intermediate rail.    Note: Abatement certification IS required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.23 C01

Serious Gravity 5 2 instances 1 exposed
Issued
Mar 27, 2012
Abate by
Apr 17, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.23(c)(1): Every open-sided floor or platform 4 feet or more above adjacent floor or ground level was not guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section on all open sides except where there is an entrance to a ramp, stairway, or fixed ladder:    (a)	Bulk tank ladder to Production roof: On 12/29/2011 and at times prior thereto, an intermediate ladder landing at 9 6 high was not protected to prevent a worker from walking directly into the opening.    (b)	Production: On 12/29/2011 and at times prior thereto, workers accessed a 9 3 high platform that was not protected by standard railing to service a vitamin E tote.    Note: Toeboards are only required where tools, machine parts, or materials are likely to be used on the runway.    Note: Abatement certification IS required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 C02 I

Serious Gravity 5 2 instances 20 exposed
Issued
Mar 27, 2012
Abate by
Apr 17, 2012
Penalty
Initial $2,625 · Current $1,250 Reduced
29 CFR 1910.219(c)(2)(i): Exposed part(s) of horizontal shafting seven -7 feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting:    (a)	Load Out Pump 2: On 12/29/2011 and at times prior thereto, The horizontal shaft was not completely guarded against accidental contact.    Note: Abatement certification IS required for this item.
Recent events (2)
  • — I (S) $1250
  • — Z (S) $2625

1910.305 E01

Other-than-serious 2 instances 20 exposed
Issued
Mar 27, 2012
Abate by
May 8, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(e)(1): Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in damp or wet locations were not installed to prevent moisture or water from entering and accumulating within the enclosures and were not mounted so there is at least 6.35-mm (0.25-in) airspace between the enclosure and the wall or other supporting surface:    (a)	Load Out Pump 2: On 12/29/2011 and at times prior thereto, an electrical control box was subject to water invasion due to improperly connected conduit.     (b)	Load Out Pump 2: On 12/29/2011 and at times prior thereto, an electrical control box in a wet location (outdoors) was mounted directly to a concrete curb with inadequate airspace between the box and mounting surface.    Note: Abatement certification IS required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Performix Nutrition Systems, LLC's full OSHA safety record →