Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PAYNE CONSTRUCTION, INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PAYNE CONSTRUCTION, INC in AAFES SHOPETTE PROJECT, CAMP WITHYCOMBE BLDG. 6400, CLACKAMAS, OR 97015 (NAICS 236220). OSHA activity number 331108456.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Payne Construction, INC — free Get an email when a new federal OSHA severe-injury report for Payne Construction, INC is published. One employer, no account, unsubscribe in one click.
Site address
AAFES SHOPETTE PROJECT, CAMP WITHYCOMBE BLDG. 6400
City
CLACKAMAS
State
OR
ZIP
97015
Mailing
5404 NE 112TH AVE, PORTLAND, OR 97220
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
2
Ownership type
A

5 citations on file for this inspection.

1926.34 C

Serious Gravity 1 3 exposed
Issued
Feb 13, 2012
Penalty
Initial $1,800 · Current $1,260 Reduced
29 CFR 1926.34(c):     Means of egress was not continually maintained free of all obstructions or impediments to full instant use in the case of fire or other emergency.      Camp Withycombe AAFES Project-    (a) Employee's means of egress through hallways and entryways were obstructed by flexible electrical cords hanging from ceilings and scattered throughout passageways and exit routes.
Recent events (2)
  • — I (S) $1260
  • — Z (S) $1800

1926.403 B02

Serious Gravity 1 2 exposed
Issued
Feb 13, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.403(b)(2):     Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:    Camp Withycombe AAFES Project-    (a) The Tripp-Lite Super 7 power strip was used to supply power to two temporary string lights and two heater units using flexible extension cords. Instructions indicate not to plug in extension cords and intended application is for home/office.
Recent events (1)
  • — Z (S) $0

1926.405 G02 IV

Serious Gravity 1 2 exposed
Issued
Feb 13, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(2)(iv):     Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:    Camp Withycombe AAFES Project-    (a) The 240 volt flexible electrical power cord was hanging from the ceiling and was not properly connected to the strain relief hardware of its attached outlet box.
Recent events (1)
  • — Z (S) $0

1926.20 B02

Other-than-serious 2 exposed
Issued
Feb 13, 2012
Abate by
Mar 6, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.20(b)(2):     The employer did not initiate and maintain a safety program which provides for frequent and regular inspections of jobsites, materials, and equipment to be made by a competent person Camp Withycombe AAFES Project-    (a) The safety program was not maintained at the work site, as evidenced by:    - temporary lighting fixtures missing protective cages  - a lack of strain relief on an 240 volt electrical cord  - tripping and struck-by hazards caused by electrical cords  - improper use of a Tripp-Lite Super 7 power strip  - safety barrier not maintained for stairway without handrails.
Recent events (1)
  • — Z (O) $0

1926.405 A02 II E

Other-than-serious 2 exposed
Issued
Feb 13, 2012
Abate by
Mar 6, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.405(a)(2)(ii)(E):     Lamps used in temporary wiring for general illumination were not protected from accidental contact or breakage:    Camp Withycombe AAFES Project-    (a) Three temporary string light fixtures had their bulbs exposed and were not protected from breakage.
Recent events (1)
  • — Z (O) $0

View Payne Construction, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331108456.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.