Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SANMINA SCI

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SANMINA SCI in 300 INDUSTRIAL AVE, TURTLE LAKE, WI 54889 (NAICS 326121). OSHA activity number 331109108.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sanmina SCI — free Get an email when a new federal OSHA severe-injury report for Sanmina SCI is published. One employer, no account, unsubscribe in one click.
Establishment
SANMINA SCI
Site address
300 INDUSTRIAL AVE
City
TURTLE LAKE
State
WI
ZIP
54889
Mailing
300 INDUSTRIAL AVE, TURTLE LAKE, WI 54889
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326121
Employees
241
Ownership type
A

8 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 1 instance 5 exposed
Issued
Mar 5, 2012
Abate by
Jun 22, 2012
Penalty
Initial $3,400 · Current $1,700 Reduced
29 CFR 1910.23(c)(1): Open-sided floor(s) or platform(s) 4 feet or more above the adjacent floor or ground level were not guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)(i) through (v)), on all open sides:  a) In the production area; Employees were not protected from falling to lower levels as they performed maintenance, servicing and cleaning functions while working from the top of the machines.
Recent events (2)
  • — I (S) $1700
  • — Z (S) $3400

1910.110 F02 II

Serious Gravity 5 1 instance 10 exposed
Issued
Mar 5, 2012
Abate by
Mar 26, 2012
Penalty
Initial $3,400 · Current $1,700 Reduced
29 CFR 1910.110(f)(2)(ii): Containers stored inside were located near exits, stairways, or in areas normally used or intended for the safe exit of people:  a) At the exit in the storage area; Tanks containing liquefied petroleum gas were stored at the exit route near the exit door.
Recent events (2)
  • — I (S) $1700
  • — Z (S) $3400

1910.151 C

Serious Gravity 1 1 instance 4 exposed
Issued
Mar 5, 2012
Abate by
Mar 26, 2012
Penalty
Initial $2,550 · Current $1,275 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  a) At the forklift charging station; The employer did not have adequate drenching facilities for exposure to corrosive materials within the immediate work area.
Recent events (2)
  • — I (S) $1275
  • — Z (S) $2550

1910.305 B01 II

Serious Gravity 5 1 instance 6 exposed
Issued
Mar 5, 2012
Abate by
Mar 26, 2012
Penalty
Initial $3,400 · Current $1,700 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  a) At the two conveyor electrical panels; The electrical cabinets had pre-punched knockouts that were missing.
Recent events (2)
  • — I (S) $1700
  • — Z (S) $3400

1910.305 G01 IV A

Serious Gravity 5 1 instance 10 exposed
Issued
Mar 5, 2012
Abate by
Apr 27, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and cables were used as a substitute for the fixed wiring of a structure:   a) Throughout the production area; Numerous extension cords were located in the production area and used to provide electrical power to prodution equipment.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 5 1 instance 6 exposed
Issued
Mar 5, 2012
Abate by
Apr 27, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  a) In the production area; The strain relief on the fan and the electrical outlet boxes at the work tables was inadequate as it did not prevent the electrical wires from being pulled away from the teminal screws.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.333 C02

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 5, 2012
Abate by
Mar 26, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.333(c)(2): Qualified persons were not capable of working safely on energized circuits and were not familiar with the proper use of special precautionary techniques, personal protective equipment, insulating and shielding materials, and insulated tools:  a) In the facility; Electrical work was being performed by an employee that had not been trained as a qualified person.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D04 I

Other-than-serious 1 instance 3 exposed
Issued
Mar 5, 2012
Abate by
Mar 26, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:  a) At the conveyors; The conveyors were not locked out prior to employees climbing on them to access the electrical panels for the presses on cells 211 and cell 213.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Sanmina SCI's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331109108.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.