TURTLE LAKE, WI —
OSHA Inspection: SANMINA SCI
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of SANMINA SCI in 300 INDUSTRIAL AVE, TURTLE LAKE, WI 54889 (NAICS 326121). OSHA activity number 331109108.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SANMINA SCI
- Site address
- 300 INDUSTRIAL AVE
- City
- TURTLE LAKE
- State
- WI
- ZIP
- 54889
- Mailing
- 300 INDUSTRIAL AVE, TURTLE LAKE, WI 54889
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326121
- Employees
- 241
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.23 C01
- Issued
- Mar 5, 2012
- Abate by
- Jun 22, 2012
- Penalty
- Initial $3,400 · Current $1,700 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floor(s) or platform(s) 4 feet or more above the adjacent floor or ground level were not guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)(i) through (v)), on all open sides: a) In the production area; Employees were not protected from falling to lower levels as they performed maintenance, servicing and cleaning functions while working from the top of the machines.
Recent events (2)
- — I (S) $1700
- — Z (S) $3400
1910.110 F02 II
- Issued
- Mar 5, 2012
- Abate by
- Mar 26, 2012
- Penalty
- Initial $3,400 · Current $1,700 Reduced
General-duty citation text
29 CFR 1910.110(f)(2)(ii): Containers stored inside were located near exits, stairways, or in areas normally used or intended for the safe exit of people: a) At the exit in the storage area; Tanks containing liquefied petroleum gas were stored at the exit route near the exit door.
Recent events (2)
- — I (S) $1700
- — Z (S) $3400
1910.151 C
- Issued
- Mar 5, 2012
- Abate by
- Mar 26, 2012
- Penalty
- Initial $2,550 · Current $1,275 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: a) At the forklift charging station; The employer did not have adequate drenching facilities for exposure to corrosive materials within the immediate work area.
Recent events (2)
- — I (S) $1275
- — Z (S) $2550
1910.305 B01 II
- Issued
- Mar 5, 2012
- Abate by
- Mar 26, 2012
- Penalty
- Initial $3,400 · Current $1,700 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) At the two conveyor electrical panels; The electrical cabinets had pre-punched knockouts that were missing.
Recent events (2)
- — I (S) $1700
- — Z (S) $3400
1910.305 G01 IV A
- Issued
- Mar 5, 2012
- Abate by
- Apr 27, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and cables were used as a substitute for the fixed wiring of a structure: a) Throughout the production area; Numerous extension cords were located in the production area and used to provide electrical power to prodution equipment.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G02 III
- Issued
- Mar 5, 2012
- Abate by
- Apr 27, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: a) In the production area; The strain relief on the fan and the electrical outlet boxes at the work tables was inadequate as it did not prevent the electrical wires from being pulled away from the teminal screws.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.333 C02
- Issued
- Mar 5, 2012
- Abate by
- Mar 26, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.333(c)(2): Qualified persons were not capable of working safely on energized circuits and were not familiar with the proper use of special precautionary techniques, personal protective equipment, insulating and shielding materials, and insulated tools: a) In the facility; Electrical work was being performed by an employee that had not been trained as a qualified person.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D04 I
- Issued
- Mar 5, 2012
- Abate by
- Mar 26, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: a) At the conveyors; The conveyors were not locked out prior to employees climbing on them to access the electrical panels for the presses on cells 211 and cell 213.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Sanmina SCI
View Sanmina SCI's full OSHA safety record →
More inspections in this industry (NAICS 326121)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331109108.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.