Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: CHASE & MERRILL, LLC

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of CHASE & MERRILL, LLC in 7 ALLEN ST, HANOVER, NH 03755 (NAICS 238210). OSHA activity number 331110452.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Chase & Merrill, LLC for free Get an email when a new federal OSHA severe-injury report for Chase & Merrill, LLC is published. One employer, no account, unsubscribe in one click.
Site address
7 ALLEN ST
City
HANOVER
State
NH
ZIP
03755
Mailing
197 NORTH MAIN ST. #1, BOSCAWEN, NH 03303
Inspection type
Unprogrammed Related (G)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
2
Ownership type
A

3 citations on file for this inspection.

1926.21 B02

Serious Gravity 5 2 instances 2 exposed
Issued
Jun 28, 2012
Abate by
Jul 20, 2012
Penalty
Initial $3,000 · Current $3,000
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury.    a. Site- Employees who were not protected from electrical shocks and burns were not provided with electrical safe work practice training from the employer.
Recent events (2)
  • · I (S) $3000
  • · Z (S) $3000

1926.417 B

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 28, 2012
Abate by
Jun 29, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.417(b): Equipment or circuits that were de-energized were not rendered inoperative.    a. Site- Employees removing electrical installations and wiring were not protected from electric shocks and burns where the circuits were not rendered inoperative.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.95 A

Serious Gravity 5 2 instances 2 exposed
Issued
Jun 28, 2012
Abate by
Jun 29, 2012
Penalty
Initial $3,000 · Current $0 Reduced
29 CFR 1926.95(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, were not provided.    a. Site- Employees doing voltage testing were not protected from electrical shocks and burns where voltage rated gloves were not used or provided.
Recent events (2)
  • · I (S) $0
  • · Z (S) $3000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331110452.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.